Advertisement

Quick Links

User Manual
ADAM-3600-C2G
iRTU User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Advantech ADAM-3600-C2G Series

  • Page 1 User Manual ADAM-3600-C2G iRTU User’s Manual...
  • Page 2 No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
  • Page 3 Declaration of Conformity The ADAM-4000 series developed by Advantech Co., Ltd. has passed the CE test for environmental specifications when operated within an industrial enclosure (ADAM- 4950-ENC). Therefore, in order to protect the ADAM modules from being damaged by ESD (Electric Static Discharge), we strongly recommend that the use of CE-com- pliant industrial enclosure products when using any ADAM module.
  • Page 4 ADAM-3600 Series User Manual...
  • Page 5: Table Of Contents

    Contents Chapter Introduction..........1 Product Concept &Target Market.............. 2 Figure 1.1 iRTU Application Architecture........2 Chapter Specifications ........3 Product Key Features ................4 ADAM-3600-C2G Specification..............5 2.2.1 ADAM-3600-C2G Specification of Main Unit ........ 5 2.2.2 Expansion Module Specifications ..........7 LED Indicators................... 8 Figure 2.1 LED Indicator..............
  • Page 6 Chapter Advantech iRTU Studio ....21 iRTU Studio Introduction................. 22 Using iRTU Studio for Configuration and Management......22 4.2.1 Project Initialization..............22 Figure 4.1 Creating a new project ..........22 Figure 4.2 Adding Devices and Editing ........23 Figure 4.3 Copying Devices ............23 Figure 4.4 Deleting Devices ............
  • Page 7 Appendix B Interface Definition ......47 Interface Definitions ................48 B.1.1 Communication Ports..............48 B.1.2 I/O Interface Definition ..............50 ADAM-3600 Series User Manual...
  • Page 8 ADAM-3600 Series User Manual viii...
  • Page 9: Chapter 1 Introduction

    Chapter Introduction...
  • Page 10: Product Concept &Target Market

    Product Concept &Target Market The ADAM-3600-C2G is an Intelligent Remote Terminal Unit / iRTU, mainly for the oil & gas and water industries. Intelligent network nodes in loT can control the down- stream field devices to complete delivery tasks, transfer data to upstream devices wired or wirelessly.
  • Page 11: Chapter 2 Specifications

    Chapter Specifications...
  • Page 12: Product Key Features

    An RTU is usually applied to a wide range of monitoring, such as oil field or oil pipe- lines. In wide area environments, wired communication often has cost and mainte- nance problems. The ADAM-3600-C2G series two built-in Mini-PCle cards slots and can support two types of different wireless communication interfaces. The supported...
  • Page 13: Adam-3600-C2G Specification

    NodeID as identification facilitate remote batch configuration ADAM-3600 has a six bit DIP-switch on board which can be identification for 64 devices on the field. Through an ordinary cable, it could download configuration doc- uments into RTU devices (with a maximum of 64), and customers could find out the sources of faults through ID codes when variations encountered in the performance of RTU.
  • Page 14 2.2.1.2 Input / Output Specification Analog Input Channel 8, differential Input Type Voltage, Current Voltage/Current Range ±10V, ±2.5V, 0~20mA, 4~20 mA Resolution 16-bit Sampling rate 10 samples/second (total)  Input Impedance Accuracy ±0.1% or better (Full Scale) CMR @ 50/60 Hz 120 dB NMR @ 50/60 Hz 100 dB...
  • Page 15: Expansion Module Specifications

    2.2.2 Expansion Module Specifications ADAM-3600-C2G support four slots expansion can support different type I/O mod- ules in one integrated unit. 2.2.2.1 ADAM-3617 (4-ch AI) Channel 4, differential Input Type Voltage, Current Voltage/Current Range ±10V, ±2.5V, 0~20mA, 4~20 mA Resolution 16-bit Sampling rate 10 samples/second (total) ...
  • Page 16: Led Indicators

    2.2.2.4 ADAM-3651 (8-ch DI/ PI ) Channel Input Type Sink (Wet Contact)/ Counter Wet Contact Input Logic0: 0 ~ 5 V Logic 1: 11~30V Rated Voltage 12/24 V Rated Input Current >5mA@12V >10mA@24V Input Filter Programmable, Default: 3ms Pulse Input Frequency 150HZ Over Voltage Protection +40 V...
  • Page 17: System Led

    2.3.1 System LED Color Function Description Green Device powered indicator. Extended function is described in 4-2-6-4. Green Control logic running indicator. Extended function is described in 4-2-6-4. Control logic error indicator. Extended function is described in 4-2-6-4. Light on, battery lower than 5V PROG Green Control by user’s program...
  • Page 18: Irtu Dimensions

    iRTU Dimensions Figure 2.2 ADAM-3600 Dimensions ADAM-3600 Series User Manual...
  • Page 19: Chapter 3 Wiring And Installation

    Chapter Wiring and Installation...
  • Page 20: Wiring

    Wiring 3.1.1 Power Supply Wiring ADAM-3600-C2G supports mains input ranging from 10 V to 30 V . Users can choose standard 12 V or 24 V C power supply. Figure 3.1 Power Supply Wiring 3.1.2 3-1-2Input / Output Wiring 3.1.2.1 Analog Input Wiring ADAM-3600-C2G equips with 8 channels AI with differential wiring type, wire as shown below:...
  • Page 21: Serial Port Wiring

    3.1.2.2 Digital Input Wiring The ADAM-3600-C2G is equipped with 8 channels DI, follow the below diagram for wiring. The pin “COM” is for positive voltage wiring and provides a pull high voltage to the unwired pins. Normally user can leave it empty, and consider wiring while the field interference is significant.
  • Page 22: Installation

    Installation 3.2.1 Wall-mounted and DIN-Rail Installation The ADAM-3600-C2G supports two types of installation: Wall-mounted and DIN-Rail Installation. For wall-mounted installation, users can fix the device on the wall with 4 screws as shown below. Figure 3.6 Wall-mounted Installation For DIN-Rail installation, follow the below diagram to put the device on the DIN-Rail, and lock the 3 lock to fix the device on the DIN-Rail Figure 3.7 DIN-Rail Installation ADAM-3600 Series User Manual...
  • Page 23: Wireless Module Installation

    3.2.2 Wireless Module Installation There are two wireless expansion interfaces under the gray cover, which supports two Mini-PCle ports, and can insert wireless LAN card. Two overlapping network cards can be installed. The below supports half-sized card while the upper supports full-size card.
  • Page 24: Writeable Label

    3.2.4 Writeable Label To make it more convenient for users to record RTU device information, we espe- cially design a writeable label on the cover. User can write any information to help to keep some important project information. Figure 3.11 Writeable Label 3.2.5 SD Card Installation The ADAM-3600-C2G supports two types of SD cards used as storage.
  • Page 25: Sim Card Installation

    3.2.6 SIM Card Installation When customers install a 3G/GPRS module, they need to insert a SIM card, follow below diagram to install the SIM card. The SIM card is micro-SIM (3FF) type. Figure 3.13 SIM Card Installation ADAM-3600 Series User Manual...
  • Page 26: Jumper/Switch Settings

    Jumper/Switch Settings 3.3.1 DIP Switch Settings ADAM-3600-C2G IO has two DIP switches as follows: Figure 3.14 DIP Switch Setting Name Meaning Description Node ID 6-bit: supports 0~63 devices ON-1/ OFF-0 1 is for high bit, 6 is for last bit, ex: [0 0 0 0 0 1] = 1 [1 0 0 0 0 0] = 32 8-ch AI Current or voltage...
  • Page 27: Jumper Settings

    3.3.2 Jumper Settings The ADAM-3600 CPU has two Jumpers as follows: Figure 3.15 Jumper Settings Name Meaning Descriptions CN14 COM1 DB9 Port select RS-232 or RS-485 RS-485 RS-232 CN15 Watchdog Enable Jumper ON- Enable OFF- Disable ADAM-3600 Series User Manual...
  • Page 28 ADAM-3600 Series User Manual...
  • Page 29 Chapter Advantech iRTU Studio...
  • Page 30 For this, Advantech developed a utility software to facilitate these tasks. Advantech iRTU Studio can be operated in Windows XP/ Windows 7 system and has the fol- lowing functions: ...
  • Page 31 4.2.1.2 Adding Devices and Editing a Project After completing the creation of the new project, users can right-click on the project name to check the project information and add new devices. To add devices, user need to input the name, device type Node ID and description. The field of password contains the default set- ting;...
  • Page 32 4.2.1.4 Deleting Devices Users can right-click on the device name and choose “delete” to delete a device in the project. Figure 4.4 Deleting Devices 4.2.2 Configuring the Data Center and Link Tag with I/O After adding a device, there will be an item "Data Center" under the added device. It is a place for user to manage data acquisition, which is an important functionality for a RTU.
  • Page 33 4.2.2.1 OnBoard I/O Configuration The ADAM-3600-C2G is equipped with 8-ch AI, 8-ch DI, and 4-ch DO ports which users can map the real input signals to the IO tag. The configuration method of analog and discrete input is different and the specific configuration method is as follows: ...
  • Page 34 Counter_EN: counter enable. The data type is discrete and the value can only be “0” or “1”. Users can set the initial value and signal reverse. When the signal reverse is “True”, it means that DI interface enable the counter function with value of “1”; Otherwise, when the signal reverse is “False”, it means that DI interface enable the counter function with the value of “0”.
  • Page 35 4.2.2.2 Serial I/O Device Configuration The ADAM-3600 has three serial ports including 1x RS232/RS485, 2 x RS485. iRTU Studio can edit, delete and add device on these three ports. Right click the “Data Center” on the left-side tree view, and select “Add Port” In the “Type”...
  • Page 36 4.2.2.3 Ethernet I/O Device Configuration ADAM-3600 is equipped two Ethernet ports; user can edit, delete and add devices through iRTU Studio. Double click or right click the “TCP” item under the “Data Center” in the left side tree view and choose “edit” as shown in the following figure to edit the port. Figure 4.10 Editing TCP Information Right click “TCP”...
  • Page 37 Double click the “I/O Tag” item to edit the tag to map with the data from Ethernet meter. Figure 4.12 Configuring a TCP Meters I/O iRTU Studio default provide 1 TCP port for Ethernet IO configuration, if user need another TCP port, please right click on the “Data Center” and select “Add Port”.
  • Page 38 4.2.2.4 Zigbee Wireless I/O Device Configuration A Zigbee wireless communication module can be added to the ADAM-3600 from COM port or USB port on PCIe-mini card socket. To get data from the Zigbee Wireless Meter, use the fol- lowing steps: Right click the “Data Center”...
  • Page 39 In the “New Meter” page, type in the name and related parameters, and click “Apply” to add meter. While the meter added, there is a new item “I/O Tag” below the meter, click the “+” in front of the port and meter to unfold it. Figure 4.15 Adding a ZigBee Meter Double click the “I/O Tag”...
  • Page 40 4.2.2.5 Computation Tag Configuration Considering oil & gas and water industry variables cannot be measured directly or the cost is very high, users can apply computation tag configuration function provided by iRTU Studio to approximate the variable through computation of the existing variables. In addition, some- times users have to program to get user tags.
  • Page 41 4.2.2.6 User Tag Configuration We mainly introduced I/O tag configuration in the former articles, while there are some non- actual I/O tags in the project configuration, which allow users to choose and configure. This is called as user tag. These user tags could be used for C language and KW language program- ming as a control signal as well as a presentation of computation results.
  • Page 42 USB into the ADAM-3600-C2G to copy the historical data in SD card. PROM indicator will always be blinking until finishing the process of copying. The historical data is stored in the form of SQLite. If users want to read the file, please contact Advantech customer service. We will help you to read the data.
  • Page 43 The “Modbus Address” is the address for client to access the tag data. Figure 4.21 Adding I/O Tags to the Modbus Address List Figure 4.22 Adding I/O Tag Information To connect with WebAccess, users should click WebAccess WhereIAm. Make sure that the physical IP address with WebAccess is right.
  • Page 44 Duration (s): communication time; it should be shorter than Periods. the default value (0) means there is no interruption during communication with WebAccess. Figure 4.23 WebAccess whereIAM 4.2.5 Connectivity Configuration The ADAM-3600-C2G is an Intelligent Remote Terminal Unit and acts as an intelligent net- work node in IoT.
  • Page 45 The relationship among connection period, connection duration and idle time is shown in the following picture. Figure 4.24 Relationship among connection period, connection duration and idle time  DTU-Four Faith PROT Protocol Figure 4.25 DTU-Four faith PROT protocol in active connection The extra parameters are also required in the DTU-Four faith PROT protocol.
  • Page 46 fd ed =>fd When the send data is as follows: 01 0a fd cd fe fe 22, the escaped data is as follows: 01 0a fd ed cd fd ee fd ee 22.  Webaccess WhereIAm Protocol Figure 4.26 Webaccess WhereIAm Protocol in active connection The additional Identifier Device parameter is required in Webaccess WhereIAm protocol.
  • Page 47 Figure 4.27 On-board I/O Settings While configuring the expansion module, please click to select the target expansion slot first and select the module from the draw down list. Then configure the related setting by click and select from the related column, please refer to the figure below: Figure 4.28 Expansion I/O Settings Click the button “Calibration”...
  • Page 48 4.2.6.2 Network Function Setting The ADAM-3600-C2G supports wired and wireless network connections to communicate with other devices. User has to configure the network environment in this section. Cable Network Settings The ADAM-3600-C2G has two Ethernet ports and users can configure them respectively. Under the concomitances that Ethernet ports supports IPv4 and IPv6, users can set RTU as DHCP or fixed IP.If users select RTU as DHCP mode, RTU will provide a default IP address when not getting an IP address.
  • Page 49 GPRS Settings In the GPRS setting section, user has to choose the GPRS connection to join the network. and make sure the Connect has been clicked: Figure 4.31 GPRS Settings If there are different communicated modes applied. Users should make scripts. Figure 4.32 GPRS Script Setting 4.2.6.3 LED Configuration...
  • Page 50  RUN Indicators Configuration ADAM-3600-C2G has two functions: data acquisition and control. When users only need data acquisition, just select “Data Collection” button. RUN indicator will blink if data acquisition function is normal. When users need data acquisition and control function, select “Data Col- lection + Softlogic”.
  • Page 51 4.3.1 Device Identification Before we start to download the configuration to the RTU device, users have to adjust the connected RTUs to be with the correct NodeID as project required. The “Device Search” will help user to explore all the RTU devices which the NodeID is men- tioned in the configured project.
  • Page 52 4.3.3 Password Settings For security, the ADAM-3600-C2G has a default password "00000000", and iRTU Studio also sets it as the default password for RTU devices. Figure 4.36 Password Information To change the password, follow the steps below: iRTU Studio connects with the RTU device, and it has been identified. Click 'password setting', select the device, input the old and new password respectively and then confirm the new password.
  • Page 53 Appendix ADAM-3600 Naming Rules...
  • Page 54 ADAM-3600 Naming Rules The ADAM-3600 includes two types of products that are ADAM-3600-A1F and ADAM-3600-C2G, which shows a difference as far as their design and features. In this Manual, we focus on the introductions of ADAM-3600-C2G. Figure A.1 ADAM-3600 Naming Rules Examples: ADAM-3600-C2GL1AE: Cortex A8 iRTU for Oil &...
  • Page 55: Appendix B Interface Definition

    Appendix Interface Definition...
  • Page 56: Interface Definitions

    Interface Definitions B.1.1 Communication Ports B.1.1.1 COM 1: RS-232/RS-485  Connection: DB-9  Baud rate: 1200~115.2k bps  RS232 signals: RxD, TxD, GND, RTS, CTS  RS485 signals: DATA+, DATA- RS-232 Signal RS-485 Signal DATA- DATA+ B.1.1.2 COM 2 & COM3: RS-485 ...
  • Page 57 B.1.1.3 USB Port  Connection: USB 2.0 1800 connect  USB signals: Vcc, Data-, Data+, GND USB Signal Data- Data+ B.1.1.4 LAN1 and LAN2: Ethernet Port  Connection: RJ-45 Base-T 1800 connect  Transfer rate: 10/100Mbps  LAN signals: TD+, TD-, RD+, RD- Signal TD‐...
  • Page 58: I/O Interface Definition

    B.1.2 I/O Interface Definition ADAM-3600 Series User Manual...
  • Page 59 ADAM-3600 Series User Manual...
  • Page 60 No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis- sion of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2015...

This manual is also suitable for:

Adam-3600-c2gl1aeAdam-3600-a1fn0ae

Table of Contents