6.4.2 Connection diagram

The following illustrations show the key connection diagrams of the drive system when supplied
with SELV and PELV power supply units:
PLC fieldbus
Master
PLC outputs /
switches or PLC
inputs / actuators
24 VDC
24 VDC
en-26
cdsx-40xxxx-xxxxx-xxx-xxx-
Axx
X2
Fieldbus IN
M12 4/5-pin
X4
1 DIN1
Digital
2 DIN2
inputs &
3 DIN3
outputs
4 DIN4
5 DOUT1
6 DOUT2
7 VCC24
8 GND
M12 8-pin
X5
Supply
M12 6-pin
Doc. no.: 5022-D056658
X1
Fieldbus OUT
M12 4/5-pin
X3
1 VCC
USB
2 D-
3 D+
4 GND
M12 4-pin
1 DC Bus +
2 DC Bus -
3 LOGIC +
FE
4 STO
5 STO GND
®
cyber
dynamic system
PC / MotionGUI 2
USB
Power supply 12-60 VDC
F1
+48 VDC nom.
GND
Revision: 01