58
Stripped cable
Cable screen
5. Lock the two parts of the lead-through plate by tightening the positioning
screws.
6. Top entry: If more than one cable go through a single grommet, the grommet
must be sealed by Loctite 5221 (catalogue number 25551).
Top entry
Electrical Installation
Conductive surface of the
screen exposed
−
Cut the screen at the midpoint of the bare part. Be careful not to cut
the conductors.
−
Turn the screen inside out to expose its conductive surface.
−
Cover the turned screen and the stripped cable with copper foil to
keep the shielding continuous.
Note:
The ground wire (if present) must not be cut.
−
Push the two parts of the lead-through plate together so that the
conductive cushions press tightly round the foil covered screen.
Side view
3ADW000352R0101 DCS800-A Installation Manual e a
Stripped part covered with