2.4.4 Cancelling the last alarm

It is good practise to cancel the alarm code from memory:
After reading the alarm, to check whether it comes up again during the diagnostic
cycle. 
After carring out the repair, to check whether it comes up again during the
test cycle.
8. Access diagnostic mode and turn the programme
selector knob to the eleventh position (alarm
reading)
Turn the knob to position 11, paying attention not
to stop at position 7, because error 32 may occur.
9. Press buttons 8 and 7 simultaneously.
10. Hold them down (about 5 seconds).
11. Once the alarm has been cancelled, E00 is
displayed.
2.4.5 Notes concerning certain alarm codes
 Configuration alarm E93: When configuration alarms are displayed (when the appliance is
switched on), the appliance stops. It is not possible to access diagnostics; the only operation
possible is to switch off the appliance (selector knob on position "0").
 Alarms EB1-EB2-EB3: In case of problems with the power supply, the appliance remains in
alarm mode until the voltage and frequency are restored to normal values or the appliance is
switched off (selector knob on position "0"). Alarm family "B" is displayed and it is not
possible to access diagnostic mode nor to use the "rapid alarm display" function. The
complete alarm can be read only when the abnormal condition has terminated.