Electrolux EDR 1000 Manual page 13

Table of Contents

Advertisement

 Alarms EB1-EB2-EB3: In the event of problems with the power supply, the appliance
remains in alarm mode until the voltage and frequency are restored to within the normal
limits or the appliance is switched off (selector knob on position "0"). Alarm family "B" is
displayed and it is not possible to access diagnostics mode nor to use the "rapid alarm
display" function. The complete alarm can be read only when the abnormal condition has
terminated.
2.4 ALARMS EDR 2000 CLUB DISPLAY
2.4.1 Displaying the alarms to the user
Operation of the alarms is configurable according to the model. Some or all of the alarms may be displayed
to the user.
The following alarms are displayed to the user:
Please close the door (when the door is open and the button Start/Pause is pressed).
Please close condenser door (when the door is open and the button Start/Pause is pressed or the door is
opened during the drying cycle).
Please clean condenser filter (this information appears at the cycle no. 80).
All other alarms are not displayed to the user (the appliance is blocked).
The service engineer can display the alarm by entering the DIAGNOSTIC SYSTEM (see par. 13.1)
All alarms, except E94, EB2 are normally displayed to the user.
When an alarm condition occurs, the drying cycle may be interrupted or paused; in some cases, for safety
reasons, a forced cooling cycle is performed. In this case, the electronic board, if possible, disconnects the
power relay from the heater unit and powers the motor of the drum cooling fan. The cycle is active until the
user switches off the appliance.
2.4.2 Reading the alarm codes
To read the last alarm code memorized in the
EEPROM of the electronic board:
 Access the diagnostic mode (see paragraph
13.1)
 Turn the programme selector knob clockwise to
the eleventh position
11, paying attention not to stop at position 7, because
.
error 32 may occur)
If no alarm conditions occurred "E00" is displayed.
2.4.3 Quick reading of the alarm
It is possible to display the last alarm even if the appliance is in normal operation mode (for ex. during the
drying programme):
 Press buttons 8 and 7 simultaneously for at least 5 seconds: the LCD display shows the last alarm. 
The alarm is displayed as long as the two buttons are held down.
 The appliance continues the cycle while the alarm codes are being displayed. If the appliance is in
programme selection mode, the options previously selected are stored in memory.