Displaying The Alarms To The User - Electrolux EDR 1000 Manual

Table of Contents

Advertisement

Higher-power (1400W) heating element.
5
Motor triac for ventilation.
Both branches of the heater unit.
6
Motor triac for ventilation.
Conductimetric sensor. This check has duration
of 4 sec. (1 sec. to create the short circuit).
The phase/warning LEDs flash during this
7
period. If the result is correct at the end, the
LEDs remain lit; if not, the LEDs flash and alarm
E32 is displayed.
Conductimetric sensor. This check has duration
of 4 sec. The phase/warning LEDs flash during
8
this period. If the result is correct at the end, the
LEDs remain lit; if not, the LEDs flash
continuously.
Door opening Triac. After 2 attempts, if the door
9
does not open, an alarm is displayed.
Coil of the door interlock.
Floating switch.
10
Canister fill pump.
Reading/cancellation of the last alarm code
Turn the knob till position 11, paying attention
11
not to stop at position 7, because error E32 may
occur.
All the LEDs light in sequence.
12-13-14-15
When a button is pressed, the corresponding
LED lights and the buzzer sounds.
2 Allarms
2.1 ALARMS EDR 1000

2.1.1 Displaying the alarms to the user

Operation of the alarms is configurable according to the model. Some or all of the alarms may be
displayed to the user.
Normally, all alarms except E44, E52, E63, E94, EB2 are displayed to the user.
When an alarm condition occurs, the drying cycle may be interrupted or paused; in some cases, for the sake
of safety, a forced cooling cycle is performed. In this case, the electronic board, if possible, disconnects the
power relay from the heater unit and powers the motor of the drum cooling fan. The cycle remains active until
the user switches off the appliance.
SOI/ADL 2009-10
Door closed. Max.
time 10 min.
Door closed. Max.
time 10 min.
Door closed.
Short circuit
between the two
drum shells.
Door closed.
Door closed
After two seconds
the triac activates.
Door closed
Tempo max. 30
sec.
Always activated
6/63
Heater unit (half
power).
Heater unit (full
power).
Control of the
conductimetric sensor
when shortcircuited.
Control of the
conductimetric
sensor when the
circuit is open.
Operation of the door
opening
Operation of the
floating switch (sump
empty)
---
---
Operation of the user
interface.
599 72 40-73