Electrolux EDR 1000 Manual page 23

Table of Contents

Advertisement

Position 3
Steamer Pump +
Steamer Water/Steam
Pipes (Visual)
Position 4
Counter clockwise
drum rotation
Position 5
Slow Clockwise drum
rotation (+ Reduced
Fan for ENV06 CRM 2
motors)
Position 6
Heater ½ power +
Clockwise drum
rotation + Full Fan
SOI/ADL 2009-10
Behaviour
Purpose of test:
Activated components:
Behaviour
Working conditions:
Purpose of test:
Activated components:
Behaviour
Working conditions:
Purpose of test:
Activated components:
Behaviour
Working conditions:
Purpose of test:
Activated components:
Behaviour
Working conditions:
If steamer tank switch is on void position, the related icon
blinks on LCD, but this not prevents the steamer to be
heated up.
To test the steamer pump and steamer in general
(pipes, connections, etc.).
Steamer heater is switched on to maintain steamer
temperature between working limits (130º - 150º).
The steamer pump is activated with short impulses
(as configured) to allow correct steam generation.
The digits on LCD show NTC2 steamer
temperature.
Phase LEDs are switched ON.
Door closed (Time out 10 min.)
To test drum motor in counter-clockwise direction.
Motor triac and relay of direction (for assembly line
request, in this position will be switched on tank
pump also).
Phase LEDs are switched ON
Door closed (Time out 10 min).
To test drum motor in clockwise direction
Drum Motor triac.
The motor performs a low-speed movement (for
assembly line request).
Main Fan motor is activated on inverse direction (to
test direction relay)
Phase LEDs are switched ON
Door closed (Time out 10 min).
To test the ½ heating power element.
High heating element, Drum Motor and Main Fan on
direct direction to give ventilation (full speed).
The digits on LCD show NTC1 drying temperature.
Phase LEDs are switched ON.
Door closed (Time out 10 min.)
23/63