Electrolux EDR 1000 Manual page 24

Table of Contents

Advertisement

Position 7
Heater full power +
Clockwise drum
rotation + Full Fan
Position 8
Conductimetric sensor.
Drum short circuit
Position 9
Conductimetric
sensor.
Drum open circuit
Position 10
Condense Tank Switch
Position 11
Condenser Tank
Switch
SOI/ADL 2009-10
Purpose of test:
Activated components:
Behaviour
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
To test the ½ & full power-heating element.
Both heating elements, Drum Motor and Main Fan
on direct direction to give ventilation full speed.
The digits on LCD show NTC1 drying temperature.
Phase LEDs are switched ON.
Door closed (Time out 10 min.)
To verify conductimetric sensor in short circuit condition.
Conductimetric sensor reading.
The step lasts 4 seconds (software configured). During
this time all phase LEDs blinks to give information of
acquisition phase. At the end of step phase LEDs are
switched OFF to give ok, otherwise a sensor alarm is
generated (if sensor alarms are enabled, otherwise
phase LEDs blinks forever).
Door closed. 1 second to create the short circuit
To verify conductimetric sensor in open circuit condition.
Conductimetric sensor reading.
The step lasts 4 seconds (software configured). During
this time all phase LEDs blinks to give information of
acquisition phase. At the end of step phase LEDs are
switched OFF to give ok, otherwise they blink forever (no
sensor alarm are managed in this step).
Door closed.
To test the tank switch
If the pump is full of water and the tank switch recognises
the condition, the pump is switched on.
Until the condense switch is on full position, phase LEDs
blink.
When the switch goes on void position the LEDs are
switched OFF.
Door closed.
To test the steamer tank switch.
The machine expects to have not water inside steamer
tank
Steamer heater and steamer pump are activated to try to
remove all water that could be on water circuit
24/63
599 72 40-73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edr 2000Edr2000 jewelEdr 2000 club display