Electrolux EDR 1000 Manual page 5

Table of Contents

Advertisement

1 DIAGNOSTICS on dryer EDR 1000 / EDR 2000 / EDR2000 JEWEL / EDR
2000 CLUB DISPLAY
1.1 Access to diagnostics
EDR 1000
EDR 2000 JEWEL
1. The appliance must be switched OFF.
2. Press START/PAUSE and the option buttons simultaneously.
3. Holding these two buttons down, switch the appliance ON by turning the programme selector knob one
position clockwise.
4. Continue to hold down the buttons until the LEDs begin to flash and the buzzer sounds (about 5
seconds).
1.2 Exiting the diagnostics system
To exit the diagnostics system, turn the programme selector knob to zero to switch the appliance OFF, then
switch it ON and OFF again.
Selector
position
All the LEDs light in sequence.
1
When a button is pressed, the corresponding
LED lights and the buzzer sounds.
Floating switch.
2
Canister fill pump.
Motor triac and relay.
3
Canister fill pump always powered.
4
Triac motor in stepping operation.
SOI/ADL 2009-10
Components activated
5/63
EDR 2000
EDR 2000 CLUB DISPLAY
Operating
Function checked
conditions
Operation of the user
Always activated.
interface.
Door closed. Max.
Operation of the
time 30 sec. Sump
floating switch and
full (0.7 litres
canister fill pump.
approx.)
Controls
Door closed. Max.
time 10 min.
counterclockwise
Pump 30 sec.
drum rotation.
Control of clockwise
drum rotation (low
Door closed. Max.
speed for visual
time 10 min.
inspection of drum
shell assembly).
599 72 40-73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edr 2000Edr2000 jewelEdr 2000 club display

Table of Contents