Electrolux EDR 1000 Manual page 27

Table of Contents

Advertisement

Position 6
Clockwise drum
rotation + Main Fan +
compressor
Position 7
Conductimetric sensor.
Drum short circuit
Position 8
Conductimetric sensor.
Drum open circuit
Position 9
Condense Tank Switch
SOI/ADL 2009-10
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
Purpose of test:
Activated components:
Behaviour:
Working conditions:
The digits on LCD show NTC1 drying temperature.
Door closed (Time out 10 min.)
To test motor in clockwise direction, circulation fan
motor TRIAC, the function of the main fan and the
compressor
Drum Motor on clockwise direction, main ventilation
motor, compressor motor and the compressor
cooling fan.
The digits on LCD show NTC1 drying temperature.
Door closed (Time out 10 min.)
On completion of this test, the compressor re-starts
only after a pause of 5 minutes.
To verify conductimetric sensor in short circuit
condition.
Conductimetric sensor reading.
The step lasts 4 seconds (software configured).
During this time all phase LEDs blinks to give
information of acquisition phase. At the end of step
phase LEDs are switched OFF to give ok, otherwise
a sensor alarm is generated (if sensor alarms are
enabled, otherwise phase LEDs blinks forever).
Door closed. 1 second to create the short circuit
To verify conductimetric sensor in open circuit
condition.
Conductimetric sensor reading.
The step lasts 4 seconds (software configured).
During this time all phase LEDs blinks to give
information of acquisition phase. At the end of step
phase LEDs are switched OFF to give ok, otherwise
they blink forever (no sensor alarm are managed in
this step).
Door closed.
To test the tank switch
If the pump is full of water and the tank switch
recognises the condition, the pump is switched on.
Until the condense switch is on full position, phase
LEDs blink.
When the switch goes on void position the LEDs are
switched OFF.
Door closed.
27/63