NEXA MODULAR G2+ AUDIO AND VIDEO DOOR ENTRY SYSTEM - BUILDING
FA-G2+ POWER SUPPLY
De
scrip
tion of the FA-G2+ power supply:
B
A
N
L
12240100
INPUT ~100-240V
FA-G2+
0.8A 50-60Hz
OUTPUT
±
BUS 30V 2V 1. A
5
BUS BUS
GOLMAR S.A. C/ Silici, 13 08940 - SPAIN
Specification
Input Voltage:
Input Frequency:
Rated Output Voltage:
Rated Output Current:
Working Temperature:
Dimensions:
nstallation
I
of the FA-G2 power supply:
The fitting and handling of the power supply must be carried out by authorised personnel in the absence of electrical
current.
Install the power supply in a dry, protected and ventilated location. Make sure that the vents are not obstructed. Use a
DIN 46277 rail for fastening (8 elements).
Note that current regulations stipulate that the power supply must be protected by a circuit breaker.
To prevent electric shock, do not remove the protective cover without first disconnecting the power supply. Replace it
once all connections have been made.
Connect the wires to the installation terminals following the instructions in the diagrams.
V02
MADE IN CHINA
PL
BUS(M) BUS PL
(
D
E
100~240Vca
50~60 Hz
3
1,5
-10ºC ~ 40ºC
140*90*60mm
+
A. On/off indicator light.
B. Protective cover for the current input.
C. Detail of current input terminals without protective
)
cover.
D. Fastening tab on DIN rail.
E. Installation terminals.
0 Vdc
± 2V
A
C
33
Need help?
Do you have a question about the Nexa Modular G2+ and is the answer not in the manual?
Questions and answers