Mounting the sensor for oil temperature monitoring
1476 Sensor pocket
1477 Sealing cap
1475 Resistance thermometer comprising
Figure 5-4
Procedure
1. Remove the sealing cap 1477 from the sensor pocket 1476.
2. Unscrew the cable gland ②, ③, ④ on the sensor cable ⑤.
3. Carefully insert the sensor ① into the sensor pocket 1476 until to the base of the drill hole.
4. Screw the intermediate unit ② into the drill hole of the sensor pocket 1476 using SW11 and
4 Nm of tightening torque.
5. Insert the sealing element ③ into the intermediate unit ②.
6. Tighten the compression nut ④ using SW11 and 4 Nm of tightening torque.
You have mounted the sensor for oil temperature monitoring.
BA 2030 (2KJ4)
Operating Instructions, 07/2020, A5E50009094A/RS-AL
①②③④⑤
Sensor
Mounting the sensor for oil temperature monitoring
5.4 Installing the oil temperature monitoring device
Intermediate fitting
Sealing element
Compression nut
Sensor cable
Commissioning