Takex PIR-T40NAM Instruction Manual page 8

Triple mirror passive sensor, vertical curtain protection
Table of Contents

Advertisement

Alarm contact output changeover setting (3 of mode selector 2)
This setting can be used to select
the alarm output logic N.C. or N.O.
contact.
ON : N.O.
OFF : N.C.
Output for external device setting (4 of mode selector 2)
This setting can be used to set the
output time of external output.
ON : Off-delay (2+30 sec.)
(When the sensor triggers an
alarm again during off-delay
time, the timer will be reset, and
the unit will continue to output
for another 30 seconds)
OFF : One-shot (2 sec.)
Short detection distance setting (5 of mode selector 2)
When the detection distance is
less than 66'(20m), set "ON".
ON : Enabled
OFF : Disabled
■Description of LED operation
■Alarm LED operation
・Lights up (for approx. 2 sec.) → When detecting intrusion (lights up for approx. 2 seconds simultaneously with alarm output)
・Continuously lit
・Blinks (for approx. 1 min.)...
・Continuously blinks (1)
・Continuously blinks (2)... 
■Memory LED operation
・Blinks for 3 minutes, and then is lit for 47 minutes...
・Blinks for 50 minutes...
・Continuously blinks...
DIP switch 3
OFF
ON
N.C.
N.O.
(Factory set)
DIP switch 4
OFF
ON
One-shot
Off-delay
(Factory set)
DIP switch 5
OFF
ON
(Factory set)
→ Area checker position error (ends when the area checker position is reset)
(
Power voltage error (lights up after a power voltage error is detected, and ends when
power voltage returns to normal, or the power is reset)
0.5 sec.
0.5 sec.
0.5 sec.
→ During warming-up (blinks for approx. 1 minute after the power is turned ON)
0.15 sec. 0.15 sec.
0.15 sec. 0.15 sec.
0.1 sec.
0.6 sec.
0.1 sec.
(
→ Cover monitor error (starts blinking after opening the cover and closing it,
and ends when the sensor operates detection twice after
a lapse of 10 seconds)
Anti-masking error (start blinking when the anti-masking error is detected and
stops when the sensor operates detection twice after ten
seconds following recovery.)
0.15 sec.
0.15 sec.
0.85 sec.
→ Self diagnosis error (starts blinking when a self diagnosis error is detected, and ends when the unit is
normally recovered, or the power is reset)
0.25 sec. 0.25 sec.
0.25 sec. 0.25 sec.
→ When memory is indicated [auto reset operation: light goes off after blinking for 3 minutes, and then is lit
0.15 sec.
0.15 sec.
0.15 sec.
0.15 sec.
0.15 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.6 sec.
0.1 sec.
→ When memory is indicated [auto reset operation: light goes off after blinking for 50 minutes]
0.15 sec. 0.15 sec.
0.15 sec. 0.15 sec.
0.1 sec.
0.6 sec.
0.1 sec.
→ Cover monitor error (blinking for 10 seconds after opening the cover and closing it)
Anti-masking setting (7 of mode selector 2)
Enable / Disable the anti-masking
function.
ON :Enabled
OFF:Disabled
DIP Switch 1
OFF
1
2
3
4
5
6
7
8
* Keep the setting OFF in 6 , 8 of mode selector 2 for operation.
3 minutes
0.25 sec.
47 minutes
for 47 minutes] (retrigger enabled during lighting)
0.15 sec.
0.15 sec.
0.15 sec.
0.1 sec.
0.1 sec.
(retrigger enabled during lighting)
DIP Switch7
OFF
(Factory set)
Factory set
DIP Switch 2
ON
OFF
ON
1
2
3
4
5
6
7
8
Memory LED
: Red
Alarm LED
: Red
ON