VIFB13 - 03/05
Byte
Octet
Meaning
0
1
Station status 1 (Station status_1)
1
2
Station status 2 (Station status_2)
2
3
Station status 3 (Station status_3)
3
4
Master address (Diag. master_Add)
4
5
Ident_Number
5
6
Ident_Number
6
7
Header Device-related diagnosis (Ext_Diag_Data)
7
8
Device-related diagnosis 1 - Error summary
8
9
Device-related diagnosis 2 - Bit no. of faulty output
9
10
Device-related diagnosis 3 - Byte no. of faulty output
10
11
Device-related diagnosis 4 - Error bits AS-i bus slaves 0-7
11
12
Device-related diagnosis 5 - Error bits AS-i bus slaves 8-15
12
13
Device-related diagnosis 6 - Error bits AS-i bus slaves 16-23
13
14
Device-related diagnosis 7 - Error bits AS-i bus slaves 24-31