Display Messages - Yamaha MOTIF6 Owner's Manual

Music prodduction synthesizer
Hide thumbs Also See for MOTIF6:
Table of Contents

Advertisement

Display Messages

Messages
MIDI buffer full.
MIDI data error.
MIDI checksum error.
Bulk protected.
Device number is off.
Device number mismatch.
Change internal battery.
Disk or card full.
File not found.
Bad disk or card.
Disk or card not ready.
Disk or card unformatted.
Disk or card write protected.
Illegal disk or card.
Illegal file.
Illegal file name.
Read only file.
Can't make folder.
Folder is too deep.
Unknown file format.
SCSI error.
Disk or card read/write error.
Can't find associated files.
Folder not empty
Unsupported disk
Seq memory full.
Choose user phrase.
No data.
Illegal check box.
No F7 (End of Exc.)
Pattern length mismatch.
Phrase length mismatch
Phrase number overflow
Illegal input.
Illegal track number.
Illegal phrase number.
Illegal measure.
Meter mismatch
Sample memory full.
Too many samples.
Sample is too short.
Sample freq is too low.
Illegal sample data.
No sample data.
Sample is too long.
SIMM configuration error.
Multi plug-in is not in slot 3.
Effect plug-in is not in slot 1.
Plug-in 1 communication error.
Plug-in 2 communication error.
Plug-in 3 communication error.
Failed to process the MIDI data because too much data was received at one time.
An error occurred when receiving MIDI data.
An error occurred when receiving bulk data.
Bulk data or a SCSI message was received when RcvBulk was set to "protect." (See page 258.)
Bulk data cannot be transmitted/received since the device number is off.
Bulk data cannot be transmitted/received since the device numbers don't match.
The internal backup battery has no remaining power. Replace the battery.
The card or disk is full and no more data can be saved. Use a new card or disk, or make space by erasing unwanted data
from the card or disk.
The specified file was not found on the card or disk during a load operation. Try again after re-inserting/re-connecting the
card or disk.
The card or disk is unusable. Format the card or disk and try again.
A card or disk is not properly inserted in or connected to the MOTIF.
The card or disk is not formatted, or the format is unusable by the MOTIF. Check the card/disk contents.
The card or disk is write protected, or you have attempted to write to a read-only medium such as CD-ROM.
The format type of the SCSI disk or Memory card is wrong.
The file specified for loading is unusable by the MOTIF.
The specified file name is unacceptable. Try entering a different name.
You have attempted to delete, rename, or overwrite a read-only file.
No more directories can be created below the current level.
Directories below this level cannot be accessed.
The file format type is not supported by the MOTIF.
A SCSI error has occurred. Check the SCSI connections and termination.
An error occurred while reading or writing to/from SCSI disk or Memory card.
The file associated with the file to be loaded cannot be found.
You attempt to delete a folder that contains data.
The disk (memory card or SCSI device connected to the MOTIF) is not supported by the MOTIF.
The internal memory for Sequence data is full. The internal memory for Sequence data is full, preventing any further
operation (such as recording, editing, Job execution, MIDI reception/transmission, or loading from Memory card or SCSI
drive). Try again after erasing unwanted song, pattern, or user phrase data.
You have attempted to record a pattern track to which a preset phrase is assigned. If you wish to use a preset phrase as
a starting data for pattern recording, copy it to a user phrase before recording.
When a Song/Pattern Job is executed, the selected track or range contains no data. Select an appropriate track or range.
No check boxes have been checked in a Sequencer track Job which requires a check box selection. Check the
appropriate check box.
Exclusive data has been entered or changed without the necessary "End of Exclusive" byte (F7). Make sure F7 is
included.
A Pattern Job will result in the length of a Pattern being greater than 256 measures.
A Pattern Job will result in the length of a phrase being greater than 256 measures.
The maximum number of phrases (256) has been exceeded when recording, executing a Pattern Job, or editing.
An unacceptable input or value has been specified. Check the input method or value.
An unacceptable track number has been specified in the Song/Pattern mode. Select the track again.
An unacceptable phrase number has been specified in the Pattern mode. Select the phrase again.
An unacceptable measure number has been specified in the Song/Pattern mode. Select the measure again.
In the Pattern Job mode, the meter (time signature) of the destination pattern is different from the meter of the source pattern.
The sample memory is full and further sampling operations, Jobs, or load operations cannot be executed.
The maximum overall number of samples (8192) has been exceeded.
The sample length is too short and the Frequency Convert Job cannot be executed.
The sampling frequency is too low and the Frequency Convert Job cannot be executed.
The sample file specified for loading is unusable by the MOTIF.
The linked sample files cannot be found during a load operation.
The sample size is too large and the Time Stretch Job cannot be executed.
An appropriate pair of expansion SIMMs is not properly installed, or the pair is not properly matched (page 287).
The Multi-Part Plug-in board does not work because it has not been installed to slot 3. The Multi-Part Plug-in board
should be installed to slot 3.
The Effect Plug-in board does not work because it has not been installed to slot 1. The Effect Plug-in board should be
installed to slot 1.
The Plug-in board that has been installed to slot 1 does not work.
The Plug-in board that has been installed to slot 2 does not work.
The Plug-in board that has been installed to slot 3 does not work.
Information
MOTIF Appendix
Display Messages
277