12.3.12 Parameter change (Backup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be con-
trolled.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Backup memory
ADDRESS
00000100 04
Element No.
0aaaaaaa ee
Parameter No.
0aaaaaaa pp
Channel No.
0ccccccc cc
Data
DATA
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
12.3.13 Parameter request (Backup memory)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the value of the specified parameter will be transmit-
ted as a Parameter Change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Backup memory
ADDRESS
00000100 04
Element No.
0aaaaaaa ee
Parameter No.
0aaaaaaa pp
Channel No.
0ccccccc cc
End of exclusive
EOX
11110111 F7
12.3.14 Parameter change (Function call Library:
store/recall)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the specified memory/library will be stored/recalled.
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
00000110 7F
Address UU
ADDRESS
00010000 10
Address UL (function)
00ffffff ff
Address LU (number H)
0aaaaaaa aa
Address LL (number L)
0aaaaaaa aa
channel High
DATA
0ddddddd dd
channel Low
0ddddddd dd
End of exclusive
EOX
11110111 F7
function
SCENE RECALL
0x00
EQ LIB RECALL
0x01
GATE LIB RECALL
0x02
COMP LIB RECALL
0x03
EFF LIB RECALL
0x04
CHANNEL LIB RECALL
0x06
INPATCH LIB RECALL
0x07
OUTPATCH LIB RECALL
0x08
Bus to Stereo LIB RECALL
0x09
number
channel*1)
tx/rx
0-99
256
tx*2)/r
x
1-200
0-513
tx/rx
1-128
0-95
tx/rx
1-128
0-513
tx/rx
1-128
0-7
tx/rx
0-128
0-513
tx/rx
0-32
256
tx/rx
0-32
256
tx/rx
0-32
256
tx/rx
Format Details
function
Surround Monitor LIB RECALL 0x0A 0-32
AUTOMIX LIB RECALL
0x0B
SCENE STORE
0x20
EQ LIB STORE
0x21
GATE LIB STORE
0x22
COMP LIB STORE
0x23
EFF LIB STORE
0x24
CHANNEL LIB STORE
0x26
INPATCH LIB STORE
0x27
OUTPATCH LIB STORE
0x28
Bus to Stereo LIB STORE
0x29
Surround Monitor LIB STORE
0x2A 1-32
AUTOMIX LIB STORE
0x2B
*1) 0:CH1 - 55:CH56, 128:BUS1 - 135:BUS8, 256:AUX1 -
263:AUX5, 512:STEREO L - 513:STEREO R
Use 256 if the recall destination or store source is a single data
item.
Effect is 0:Effect 1–3:Effect 4
If the store destination is 16383 (0x3FFF), this indicates that
the library data has been changed by a external cause
(only transmitted by the 02R96)
*2) This is also transmitted when a program that has not been
assigned to the [Program change table] is recalled.
(Normally this would be transmitted as a program change
message.)
12.3.15 Parameter change (Function call: title)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the title of the specified memory/library will be
changed
Transmission
In response to a request, a Parameter Change message will be transmitted
on the [Rx CH].
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
00000110 7F
Function call Library
ADDRESS
00010000 10
Address UL (function)
0100aaaa 4a
Address LU (number H)
0nnnnnnn nn
Address LL (number L)
0nnnnnnn nn
title 1
DATA
0ddddddd dd
:
:
title x(depend on the library)
0ddddddd dd
End of exclusive
EOX
11110111 F7
function
SCENE LIB TITLE
0x40
EQ LIB TITLE
0x41
GATE LIB TITLE
0x42
COMP LIB TITLE
0x43
EFF LIB TITLE
0x44
CHANNEL LIB TITLE
0x46
INPATCH LIB TITLE
0x47
OUTPATCH LIB TITLE
0x48
Bus to Stereo LIB TITLE
0x49
Surround Monitor LIB TITLE
0x4A 0-32(0:response only)
AUTOMIX LIB TITLE
0x4B
12.3.16 Parameter request (Function call: title)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, a Parameter Change message will be transmitted on
the [Rx CH].
285
number
channel*1)
tx/rx
256
tx/rx
1-16
256
tx/rx
1-99
256, 16383
tx/rx
41-200
0-513, 16383 tx/rx
5-128
0-56, 16383
tx/rx
37-128
0-513, 16383 tx/rx
53-128
0-7, 16383
tx/rx
3-128
0-513, 16383 tx/rx
1-32
256, 16383
tx/rx
1-32
256, 16383
tx/rx
1-32
256, 16383
tx/rx
256, 16383
tx/rx
1-32
256, 16383
tx/rx
number
size
0-99, 256(0:response
16
only)
1-200(1-40:response only) 16
1-128(1-4:response only)
16
1-128(1-36:response only) 16
1-128(1-52:response only) 16
0-128(0-1:response only)
16
0-32(0:response only)
16
0-32(0:response only)
16
0-32(0:response only)
16
16
1-16
16