Emerson Micro Motion 5700 Installation Manual page 32

Ethernet transmitters
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Wiring the channels
March 2020
Figure 4-5: Internally-powered FO: output amplitude versus load resistance [24 VDC
(Nom) open circuit]
A. Output amplitude (V)
B. Load resistor (Ω)
Figure 4-6: Externally-powered FO wiring
A
A. Frequency Output
B. Channel C
C. 5–30 VDC (maximum)
D. 500 mA current (maximum)
E. Counter
4.2.4
Wire the Discrete Output
Wire the Discrete Output in explosion-proof, nonincendive, or nonhazardous installations.
Prerequisites
Important
Meter installation and wiring should be performed only by suitably-trained personnel
using the appropriate government and corporate safety standards.
Procedure
Wire to the appropriate output terminal and pins.
32
24
22
20
18
16
14
A
12
10
8
6
4
2
0
0
250
B
500
750
1000
B
Micro Motion 5700 Ethernet Transmitters
Installation Manual
MMI-20029768
C
D
E

Advertisement