Medema Mini Crosser M2 Service Manual page 67

Hide thumbs Also See for Mini Crosser M2:
Table of Contents

Advertisement

Medema A/S
Code Description
1800
Watchdog trip
1B10
M+ current null fault
1B12
M+ current feedback
fault
1C10
M- current null feedback
1C12
M- current feedback fault
1E08
Inhibit active
1E09
Inhibit active
1E0A
Inhibit active
2100
Software loop counter
fault
2A12
M+ voltage feedback
fault
2A10
M+ voltage null fault
2B10
M- voltage null fault
2B12
M- voltage feedback fault Trip
2C00
Battery voltage too low
Battery voltage too low
2C01
Battery voltage very low
2E00
Software loop ran out of
time
Throttle displacement
2F01
fault
3100
Bridge voltage too low
3201
Stack overflow fault
3240
Illegal state fault
Service manual P9-0157-S
Action Mode
Bars Comments
Trip
Startup
8
Trip
Startup
8
Trip
All modes
8
Trip
Startup
8
Trip
All modes
8
Note 1
All modes
Note 2
Note 1
Note 2
Note 1
All modes
Note 2
Trip
All modes
8
Trip
All modes
8
Trip
Startup
8
Trip
Startup
8
All modes
8
Trip
Startup
1
Trip
All modes
1
Trip
Drive
1
Trip
All modes
8
Trip
Startup
7
No
Startup
Ripple
Trip
All modes
8
Trip
All modes
8
Trip
All modes
8
67 of 70
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Note 1 - trip or speed limit depends on
programming
Note 2 - trucharge display depends on
programming
Note 1 - trip or speed limit depends on
programming
Note 2 - trucharge display depends on
programming
Note 2 - trucharge display depends on
programming
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Battery Voltage is below 13.5V
Battery Voltage has dipped below
13.5V
Battery Voltage has dipped below
12.5V
Internal Fault. Return to PGDT if
happening all the time.
Throttle wiper is outside neutral
deadband limits at startup - trip
condition depends upon programming
- latched trip of 7 bars, or rippling up/
down of 10 bars, or nothing.
Possible Controller Fault - Can also
occur if keyswitch is on, when battery
connections are connected to Battery
terminals or keyswitch is not operating
correctly.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Version 2.0.9 - 2018