7. Technical specifications
7.1 Technical data
Technical Specification
Input voltage
Input voltage tolerance
Stroke length
Static load (Fx), maximum
Dynamic load (Fx), maximum
Speed, no load / max. rated load
MDxxA025
MDxxA050
MDxxA100
MDxxA200
Current draw @ rated max. load
Weight
End play, maximum
Operating temperature limits, standard units
Full load duty cycle @ 25 °C
Restraining torque
Motor leads cross section
Signal leads cross section
Cable length (depending on option)
Protection class - static
Protection class - dynamic
Safety features
static load holding brake
internal end-of-stroke limit switches
overload protection, control options Xxx / Exx, Lxx, CNO
temperature monitoring, control options Xxx, CNO / Exx, Lxx
temperature compensation, control options Xxx / CNO, Exx, Lxx
voltage monitoring, , control options Xxx / CNO, Exx, Lxx
Compliances
Actuator Weight [kg (lb)]
50
1.1 (2.4)
1.2 (2.6)
Thomson Electrak
MD Actuator - Installation Manual - 2020-02
®
[mm/s (inch/s)]
[Nm (lbf-in)]
[mm
[mm
Stroke (see product label) [mm]
100
150
1.3 (2.8)
[VDC]
12
[VDC]
9 - 16
[mm]
[N (lbs)]
max. static load = max. dynamic load
[N]
[A]
[kg (lbs)]
[mm (in)]
[°C (°F)]
- 40 to + 85 (- 40 to + 185)
[%]
0 (internally restrained)
(AWG)]
2
(AWG)]
2
[m (in)]
0.3 (11.8), 1 (39.4)
200
1.4 (3.1)
Thomson
MD • •
24
18 - 32
see product label
see product label
52/43.8 (2.04/1.72)
28/18.5 (1.10/0.73)
14.5/11 (0.57/0.43)
7/5.4
(0.28/0.21)
see product label
see table below
1.2 (0.047)
see product label
0.75 (18)
0.35 (22)
IP67 / IP69K
IP66
no (self-locking)
yes
no / yes
no / yes
no / yes
no / yes
CE, ISO 13766
250
300
1.5 (3.3)
1.6 (3.5)
25