THOMSON Electrak MD Series Installation Manual page 16

Electric linear actuator
Table of Contents

Advertisement

Thomson
4.6.9 Control option LLX
In addition to all of the features included in the LXX version (section 4.6.8), LLX also includes end of
stroke indication. These outputs can be used to provide feedback that the actuator has reached it's
mechanical minimum or maximum stroke.
Since these outputs are current sinking open collector type of outputs, they will each require an external
pull-up resistor to operate effectively.
Power the actuator by connecting red to + Vdc and black to - Vdc in the power cable. To extend the
actuator apply +Vdc to violet and to retract apply +Vdc to orange in the signal cable while applying -Vdc
to grey.
LLX Control Option Specifications
Input voltage
MD12
MD24
Max. actuator current draw
Extend / retract input voltage [Vdc]
Extend / retract input current
End-of-stroke output type
End-of-stroke output max. [Vdc]
voltage
End-of-stroke output max. [mA]
current
F
Fuse
S1
Extend switch
S2
Retract switch
R1
Pull-up resistor
R2
Pull-up resistor
16
[Vdc]
9 - 16
18 - 32
[A]
see product label
9 - 32
[mA]
6 - 22
open collector
32
25
Thomson Electrak
not used
fully extended
indication output
ext/ret + Vdc
fully retracted
indication output
- Vdc
not used
MD Actuator - Installation Manual - 2020-02
®
red
black
white
blue
orange
violet
brown
grey
red/white
black/white