Technical Specifications; Technical Data - THOMSON Electrak LL Installation Manual

Electric linear actuator
Table of Contents

Advertisement

7. Technical specifications

7.1 Technical data

Technical Specification
Input voltage
Input voltage tolerance
Stroke length
Static load at fully retracted (Fx), maximum
Dynamic load (Fx), maximum
Speed (constant speed regardless of load)
LLxx-B040
LLxx-B060
Current draw @ rated max. load
Weight
(1)
End play, maximum
Operating temperature limits, standard units
Full load duty cycle @ 25 °C
Restraining torque
Motor cable lead cross section
Signal cable lead cross section
Cable length
Protection class - static
Protection class - dynamic
Safety features
static load holding brake
internal end-of-stroke limit switches
overload protection
temperature monitoring
temperature compensation
voltage monitoring
Compliances
(1) Conversion factor for kilogram to pound: 1 kg = 2.204623 lbs
Thomson Electrak
LL Actuator - Installation Manual - 2020-11
®
[Vac]
[Vdc]
[mm]
[kN (lbs)]
[N]
[mm/s (inch/s)]
[A]
[kg]
[mm (in)]
[°C (°F)]
[%]
[Nm (lbf-in)]
[mm
(AWG)]
2
[mm
(AWG)]
2
[mm (in)]
ELECTRAK LL
24
16.8 - 32
see product label
18 (4050)
see product label
30 (1.18)
15 (0.59)
see product label
(stroke [mm] × 0.006) + 7
1.2 (0.047)
- 40 to + 85 (- 40 to + 185)
see product label
0 (internally restrained)
1.5 (16)
0.5 (20)
0.3 (11.8)
IP66 / IP69K
IP66
yes
yes
yes
yes
yes
yes
CE, RoHS, EN 50155,EN 60077, EN 45545
Thomson
15

Advertisement

Table of Contents
loading