THOMSON Electrak GX Installation Manual

THOMSON Electrak GX Installation Manual

Electric linear actuator

Advertisement

Quick Links

®
Thomson Electrak
GX
Electric Linear Actuator
Installation Manual
Edition 2022-02
www.thomsonlinear.com

Advertisement

Table of Contents
loading

Summary of Contents for THOMSON Electrak GX

  • Page 1 ® Thomson Electrak Electric Linear Actuator Installation Manual Edition 2022-02 www.thomsonlinear.com...
  • Page 2 (12) months from date of manufacture. The application of this product is the responsibility of the buyer and Thomson makes no representation or warranty as to the suitability of the product for any particular use or purpose. For a copy of the entire warranty for this product that is contained in our standard terms and conditions of sale, please go to http://www.thomsonlinear.com/...
  • Page 3: Table Of Contents

    5.6 Technical data for ac input voltage units .............. 15 Ordering keys ..................16 6.1 Ordering key for dc voltage models ..............16 6.2 Ordering key for ac voltage models ..............17 ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 4: General

    1.4 Transport and storage The actuator may only be transported and stored in the original packaging supplied by Thomson. The temperature during transportation and storage must be between -25 to +65° C (-15 to +150° F). Avoid shocks to the package. If the package is damaged, check the actuator for visible damage and notify the carrier, and if appropriate also Thomson.
  • Page 5: Safety

    3. Standards 3.1 EC Declaration of incorporation of partly completed machinery We, Thomson Linear declare that this products corresponds with the directive 2006/42/EC, RoHSIII directive 2015/863, WEEE directive 2012/19/EU, low voltage directive 2014/35/UE and also with the directive of electromagnetic compatibility 2014/30/UE and that the standard EN ISO 12100:2010, Safety of machinery, have been applied.
  • Page 6: Installation

    CE marked or not and where it is manufactured. Please study the product label to determine actuator type and its performance data before starting any installation or service. If you need any assistance from Thomson, please provide the manufacturing date and the designation of the actuator(s) in question.
  • Page 7: Operation Environment

    4. If the actuator is equipped with the hand wind option, the hand wind input must have enough free space around it to allow it to be operated (section 4.4.6). Dimensions: mm [inch] * SW = Slot Width ** Flat portion dimensions ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 8 The rear and the front adapter must be fixed by a method that can restrain the torque produced by the extension tube, which for Electrak GX is 11.3 Nm (100 lbf-in). If not restrained in both ends, the extension tube (or the actuator) will rotate instead of moving.
  • Page 9 • Stop running the extension tube immediately if the slip clutch (see section 4.4.5) is engaged. • Never use any type of drill or power tool to operate the hand wind. ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 10: Electrical Installation

    0 - 15 1.5 (16) 115, 230, 400 Vac 0 - 20 (0 - 66) 0 - 6 1.5 (16) * At an ambient temperature of 30 °C (86 °F) or less. ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 11 6 and the technical specifications in section 5. brake Orange (4) Fuse White (3) Double pole double throw switch Yellow/Green Actuator motor ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 12 Potentiometer max. power Green Potentiometer linearity ± 0.25 Potentiometer output [ohm/mm] resolution 2 - 10 inch stroke 11 - 20 inch stroke 21 - 24 inch stroke Potentiometer type wirewound ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 13: Technical Specifications

    15.8 16.3 16.7 17.1 17.4 Weight, ball screw [kg] models [lbf] 15.0 15.4 15.8 16.3 16.7 17.1 17.6 18.0 18.5 38.3 Add on weight for [kg] option potentiometer [lbf] 2.86 ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 14: Technical Data For Dc Input Voltage Units

    Flying leads cross section (AWG)] 2 (14) Cable length with option pot. [mm (in)] 600 (24) Cable leads cross section (AWG)] with option potentiometer motor leads 2.5 (14) potentiometer leads 1.5 (16) ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 15: Technical Data For Ac Input Voltage Units

    [°C (F)] - 25 – 65 (- 15 – 150) Full load duty cycle @ 25 °C (77 °F) End play, maximum [mm (in)] 1.0 (0.04) Restraining torque [Nm lbf-in)] 11.3 (100) Protection class - static IP45 ® Thomson Electrak GX Actuator - Installation Manual - 2022-02...
  • Page 16: Ordering Keys

    D36C = Electrak GX, 36 Vdc, CE compliant D48C = Electrak GX, 48 Vdc, CE compliant 6. Options D12N = Electrak GX, 12 Vdc, not CE compliant N = no option D24N = Electrak GX, 24 Vdc, not CE compliant...
  • Page 17: Ordering Key For Ac Voltage Models

    5. Ingress protection rating maximum speed B = IP45 A12C05A5- = Electrak GX, 1 × 115 Vac, 1100 N, acme, 54 mm/s A12C10A5- = Electrak GX, 1 × 115 Vac, 2250 N, acme, 30 mm/s 6. Options A12C20A5- = Electrak GX, 1 × 115 Vac, 2250 N, acme, 15 mm/s N = no option A12C05B5- = Electrak GX, 1 ×...
  • Page 18 Electrak_GX_Installation_Operation_MNUK-0011-01 | 20220218TJ Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of this product for a specific application. All trademarks property of their respective owners. ©2022 Thomson Industries, Inc.

Table of Contents