THOMSON Electrak MD Series Installation Manual page 18

Electric linear actuator
Table of Contents

Advertisement

Thomson
4.6.11 Control option LLP
In addition to all of the features included in the LLX version (section 4.6.9), LXP also includes a
potentiometer providing a voltage signal for the customer to use to determine position, speed and
direction.
The end-of-stroke indication ouputs are current sinking open collector type of outputs, they will each
require an external pull-up resistor to operate effectively.
Power the actuator by connecting red to + Vdc and black to - Vdc in the power cable. To extend the
actuator apply +Vdc to violet and to retract apply +Vdc to orange in the signal cable while applying - Vdc
to grey.
LLP Control Option Specifications
Input voltage
MD12
MD24
Max. actuator current draw
Potentiometer type
Potentiometer max.
input voltage
Potentiometer max.
power
Potentiometer linearity
[ohm/mm]
Potentiometer output
resolution
MDxxA025, all strokes
MDxxA100, all strokes
MDxxA050, 50 - 250 mm stroke
MDxxA200, 50 - 250 mm stroke
MDxxA050, 300 mm stroke
MDxxA200, 300 mm stroke
Extend / retract input voltage [Vdc]
Extend / retract input current
End-of-stroke output type
End-of-stroke output max. [Vdc]
voltage
End-of-stroke output max. [mA]
current
18
[Vdc]
9 - 16
18 - 32
[A]
see product label
wirewound
[Vdc]
32
[W]
1
[%]
± 0.25
16.67
16.67
33.33
33.33
16.67
16.67
9 - 32
[mA]
6 - 22
open collector
32
25
Thomson Electrak
pot. output
fully extended
indication output
ext/ret + Vdc
fully retracted
indication output
- Vdc
pot. + Vdc
pot. - Vdc
F
Fuse
S1
Extend switch
S2
Retract switch
R1
Pull-up resistor
R2
Pull-up resistor
MD Actuator - Installation Manual - 2020-02
®
red
black
white
blue
orange
violet
brown
grey
red/white
black/white

Hide quick links: