Power supply:
Operating temperature:
1
Extended temperature ratings are available using the VFD display option. Extended ratings are:
Operating -40°C to +85°C, Storage -50°C to +85°C
Environmental (Faceplate):
Vibration:
Power consumption:
Storage temperature:
Humidity:
Dimensions:
AC Metering Accuracy:
Inputs:
Engine Speed Sensing
AC Voltage
AC Current
Engine Parameters
Digital Fault Contacts
Output contacts:
Run, Crank
Programmable
Analog Oil Pressure Measurement:
Range: 15 PSI – 150 PSI (maximum)
Pressure Accuracy Operating range 15 - 59 PSI = +-6 PSI
Analog Engine Temperature Measurement:
Range: 0-200°C (maximum)
Temperature Accuracy
Specifications subject to change without notice.
PM056 Rev 6 05/10/15
10 to 30Vdc, negative ground
-15°C to +50°C
NEMA 1
4g, 5-250Hz
5 watts (max.)
-20°C to +70°C
5 to 95% non-condensing
10.75"W x 6.75"H x 2.0"D
± 1.0%, @ 25°C Volts, Amps
± 2% @25°C KVA
100 - 10,000Hz, 3.0 - 20VAC, rms
120 - 600VAC (nominal), 0.1VA, 3 phase, 50/60Hz
0 - 5Aac (nominal), 1.5VA, 3 phase
Dedicated Senders (supplied loose)
Open or close to DC Negative
10A/240VAC, 8A/24Vdc resistive (3A inductive, 0.4pf), Form A
10A/240VAC, 8A/24Vdc resistive (3A inductive, 0.4pf), Form A
Operating range 60 - 75 PSI = +-2 PSI
Operating range 76-150 PSI = +-7 PSI
Operating range
0 - 30°C = +-8°C
Operating range 30 -100°C = +-2°C
Operating range 100 -200°C = +-8°C