4.6.4 Control option XXX
Utilizing the internal control system the actuator will:
• Stop the actuator immeditately at each end of mechanical travel.
To extend the actuator apply +Vdc to red and -Vdc to black. To retract apply -Vdc to red and +Vdc to black.
XXX Control Option Specifications
Input voltage
MD12
MD24
Max. actuator current draw
F
Fuse
S1
Double pole double throw switch
4.6.5 Control option XXP
Control option XXP works as option XXX (section 4.6.4) but also has an analog (potentiometer) output
that will provide feedback on the extension tube position.
To extend the actuator apply +Vdc to red and -Vdc to black. To retract apply -Vdc to black and +Vdc to red.
XXP Control Option Specifications
Input voltage
HD12
HD24
Max. actuator current draw
Potentiometer type
Potentiometer max.
input voltage
Potentiometer max.
power
Potentiometer linearity
[ohm/mm]
Potentiometer output
resolution
MDxxA025, all strokes
MDxxA100, all strokes
MDxxA050, 50 - 250 mm stroke
MDxxA200, 50 - 250 mm stroke
MDxxA050, 300 mm stroke
MDxxA200, 300 mm stroke
F
Fuse
S1
Double pole double throw switch
12
[Vdc]
9 - 16
18 - 32
[A]
see product label
[Vdc]
9 - 16
18 - 32
[A]
see product label
wirewound
[Vdc]
32
[W]
1
[%]
± 0.25
16.67
16.67
33.33
33.33
16.67
16.67
Thomson Electrak
not used
potentiometer output
not used
+ Vdc
- Vdc
MD Actuator - Installation Manual - 2020-02
®
red
black
white
blue
orange
violet
brown
grey
red/white
black/white
red
black
white
blue
orange
violet
brown
grey
red/white
black/white