7.7
Change fluid needle
Remove fluid needle
Fig. 10: Needle reinforcement
1.
For nozzle sizes starting with size 3.0, the reinforced needle must be unscrewed first. To do
so, remove the fluid and air nozzles (
on page 29) and then unscrew the reinforced needle ( Fig. 10/1) from the fluid needle (
Fig. 10/2).
Fig. 11: Remove fluid needle
2.
WARNING!
The closing piece ( Fig. 11/3) is under spring force!
Carefully unscrew the closing piece ( Fig. 11/3).
3.
Remove the spring ( Fig. 11/2) and fluid needle ( Fig. 11/1).
GB–30
Operating instructions
Ä Chapter 7.6 'Change air and fluid nozzles'
T-Dok-009-GB-Rev.3
mail@krautzberger.com, www.krautzberger.com