Hand-held Spray Gun HS 25
7.3
Maintenance schedule
Automatic turntable
Interval
After each use
if needed
7.4
Work after completed maintenance
Upon completion of the maintenance work, the following steps must be carried out:
n
All screw connections that were unfastened during the maintenance must be checked for a
tight fit.
n
Check whether all covers and protective equipment have been properly attached.
n
Ensure that all tools, materials and other equipment have been removed from the work area.
n
Clean the work area. Properly dispose of the leaked fluids.
7.5
Clean hand-held spray gun
WARNING!
Danger of injury due to improper cleaning!
–
Adhere to the safety data sheets of the cleaning product manufacturer.
–
Do not fully immerse the hand-held spray gun in a cleaning product.
HS 25, HS 25 HV1, HS 25 HV3
Maintenance work
Clean hand-held spray gun (
'Clean hand-held spray gun' on page 27)
Change fluid and air nozzle (
'Change air and fluid nozzles' on page 29)
Change fluid needle (
fluid needle' on page 30)
Tighten needle seals (
seals' on page 32)
Change needle seals (
seals' on page 32)
Ä Chapter 7.5
Ä Chapter 7.6
Ä Chapter 7.7 'Change
Ä Chapter 7.8 'Change
Ä Chapter 7.8 'Change
ENGLISH
Personnel
Operator
Qualified personnel
GB–27