Shutting Down - Krautzberger HS 25 Series Operating Instructions Manual

Hand-held spray gun
Hide thumbs Also See for HS 25 Series:
Table of Contents

Advertisement

Options for spray pattern adjustment
Fig. 5: Adjusting the spray pattern
The spray pattern can be impacted as follows:
n
Adjust atomisation air pressure via pressure reducer or air regulator ( Fig. 5/2).
n
Adjust fluid pressure when supplied by pumps or pressure container.
n
Adjust needle stroke with adjustment screw ( Fig. 5/3).
n
Adjust width of the spray stream with jet regulator ( Fig. 5/1).
n
Selection of the nozzle size.
6.5

Shutting down

6.5.1 Shut-down in an emergency
Proceed as follows in case of an emergency:
1.
Immediately release pull lever of the hand-held spray gun.
2.
Disrupt the compressed air supply and secure it against restart.
3.
If present, switch off material pump and pressure container.
4.
If there is no risk to your own health, evacuate people from the hazard zone.
5.
If necessary, initiate first aid measures.
6.
Commission qualified personnel to eliminate the malfunction.
7.
Prior to restart, check hand-held spray gun for functionality.