Function Test And Start-Up; Shut-Down; Temporary Shut-Down - Krautzberger KS 5 Operating Instructions Manual

Hand-held spray gun
Table of Contents

Advertisement

Material must not leak at any point!

5.3.2 Function test and start-up

1.
Point the hand-held spray gun at a test surface.
2.
Start the spraying process by activating the trigger.
3.
Assess the spray pattern.
4.
If necessary, close the material supply and switch off the pump.
5.
Release the residual energy by pulling the pull lever.
6.
Replace the fluid nozzle
on page 37.
7.
If necessary, turn the fluid nozzle in the desired direction (adjustable by 360°).
8.
Tighten the nozzle nut again.
9.
Guide the spray jet in even movements across the work piece.
10.
End the spraying process by releasing the pull lever.
5.4

Shut-down

5.4.1 Temporary shut-down

Fig. 4: Temporary shut-down
1.
Disrupt the spraying process by releasing the pull lever ( Fig. 4/1).
2.
Close the material supply and switch off the pump if necessary.
3.
Release the residual energy by activating the pull lever ( Fig. 4/1).
GB–22
Operating instructions
Ä Chapter 6.6 'Replace valve seat screw and fluid nozzle'
T-Dok-653-GB-Rev.0