PROBLEM SOLVING

Problem solving table

Condition
Portions of the prints are deleted.
The prints are light overall or have
light areas.
The tracing paper has wrinkles.
Image is missing on left and right
sides of the print when using the
Scale-to-fit option
46
The table below lists some conditions that may occur during the
operation of the printer. You may be able to resolve the problems
by following the suggested solutions in the table. For problems
beyond the scope of this table, call for service.
Table 4. Problem-Solving Table
Causes
The media may be damp.
The print density may be too light.
The media may be too damp.
The media may be too dry.
When using the Scale-to-fit option
the margins may have been set 0
(zero)
Suggested Solutions
Check the condition of the media. If
damp, replace it.
Store the media in a sealed
package or bag.
Use the Printer Menu to adjust the
print density. Refer to "Adjusting
the print density" in this manual.
If media is damp, replace it.
Use a sealed media drawer.
Store the media in a sealed
package or bag.
Use a sealed media drawer.
Store the media in a sealed
package or bag.
Do not use a zero margin setting
when using Scale-to-fit. Try adding
a margin and increasing it, if
necessary, until the image is on the
print.