Table A-9 System Commands (Continued)
Setup the
[:]SYSTem[<channel>]:REMote:SOURce
Current
:CURRent[:NISOlated]
control source
for Non-
Isolated APG.
Set Front
[:]SYSTem[<channel>]:REMote:STATe
Panel lock
state.
Query SCPI
[:]SYSTem[<channel>]:VERSion?
Version
SCPI Help
[:]SYSTem[<channel>]:HELP[:HEADers]?
Legacy Help
[:]SYSTem[<channel>]:HELP:LEGacy?
Command
[:]SYSTem[<channel>]:HELP:SYNTax?
Syntax Help
Alter or query the state of
?|LOCal|AVOLtage
the remote programming
|ARESistive
non isolated current APG
source.
Change front panel control
?|LOCal|REMote
mode
Returns the SCPI version
to which the instrument
complies. Format is
YYYY.V
Query system for all
supported SCPI command
headers.
Query the system for all
supported Xantrex legacy
commands.
Query the system for the
<COMMAND>
syntax of a command. The
command should be input
after the query as a string
parameter. To enter a
command you should do
this by typing the
command as you would on
the command line without
parameters. To find all
command headers see
[:]SYSTem:HELP
[:HEADERS]?
Yes
Yes
Yes
Yes
Yes
Yes