Table A-9 System Commands (Continued)
Self Test
[:]SYSTem[<channel>]:TEST?
ID Query
[:]SYSTem[<channel>]:IDENtify
Save User
[:]SYSTem[<channel>]:SAVE
Preset
Recall User
[:]SYSTem[<channel>]:RECall
Preset
(previously
saved)
Query System
[:]SYSTem[<channel>]:ERRor[:NEXT]?
Error
Query System
[:]SYSTem[<channel>]:ERRor:CODE[:NEXT]
Error Code
?
Query the
[:]SYSTem[<channel>]:ERRor:COUNt?
Error Queue
for the
number of
entries.
Select Voltage
[:]SYSTem[<channel>]:COMMunicate
Analog
:APRogram:LEVel[:VOLTage][:ISOLated]
Programming
Input Voltage
Input Level/
Range
Perform unit Self test,
returns 0 if pass, non zero
value for failure.
Query device ID string.
Save the user preset values.
<Setting Index
Select any slot from 1-5.
(1–5)>
Load the user preset
<Setting Index
values. Select any slot from
(1–5)>
1-5.
Returns the next error in
the instrument's error
queue
Returns the error code only
for the next error in the
instrument's error queue.
Returns the number of
errors currently in the error
queue.
Select level for Voltage
?|<Level (2–
APG. Level can be between
10)>|MAXimum|MI
2 -10 volts.
Nimum
Yes
Yes
No
No
Yes
Yes
Yes
Yes