4. Machine fails to dispense oil from tip.
a. Oil pump motor has failed.
b. Pump has failed.
c. Pump belt is broken.
d. Oil control valve has failed.
e. PLC oil control valve output 100CH 07 failed.
f. Filter is clogged.
g. No oil in tank and the float failed to error machine.
5. Conditioner (oil) loads not ending at correct footage.
a. Oil Head not running at correct speed; Check Oil and Cleaner Heads for lubrication.
b. Machine speeds are not set correctly.
6. Oil Valve time has increased.
a. Oil Head is not running at correct speed, check oil and cleaner heads for lubrication.
b. Board counting target loose.
c. Wrong program was run or someone has changed the program (#1 culprit).
d. Belts are too tight on one or both of the moving heads.
e. Shaft bushings need lubricated.