Kegel FLEX 17-5801 Operator's Manual page 124

Table of Contents

Advertisement

shown as "A" in the diagram). Hold the end bell containing the rotor (as
shown on opposite page) with tubing retainer grooves pointing down.
Remove old tubing.
5.
Place new tubing (which is broken in at the factory before shipping) in the
right groove and against the first two rollers. Hold tubing with your thumb.
Near the groove, insert the smaller prong of the loading key between the top
of the rotor and tubing. Push key in as far as possible.
6.
Push down and turn the key counter-clockwise completely around the rotor.
The key will push the tubing uniformly into the end bell assembly. Hold the
second end of tubing. Remove the key.
7.
Position the other end bell on top and press the end bells together. Be careful
not to pinch the tubing. If the end bells do not snap tightly together you need
to reload the tubing. If necessary, turn the key in the slot on rotor shaft to
adjust tubing.
8.
With key in slot on rotor shaft, turn the key to align tang on rotor shaft with
slot in motor drive shaft. Point tubing retainer grooves up. Shift the pump
head slightly until it snaps on the alignment pins (if present).
9.
Replace the stem elbows in the new tubing if necessary. Make sure the
elbows are facing the correct direction.
10.
Re-attach the cleaner pump to the mount plate.
DO NOT OVER TIGHTEN THE MOUNTING SCREWS. DAMAGE TO THE PUMP MAY OCCUR.
11.
Press the stems back into the quick disconnect fittings.
112
Part #: 158-8404D
A. End Bells
B. Rotor Assembly
C. Thrust Washer (2)
D. Tubing Loading Key
E. Mounting Screws (4)
For parts identification only!
Parts not sold individually