Below is a chart to determine the amount of Water and the amount of Cleaner that should
be dispensed during testing.
REGULAR CONCENTRATE: (example Defense C)
If you were to test the water output at 5:1, you would see by the chart that a total volume of
25.00mL would be dispensed. The cleaner, which puts out 2 times the amount during the
test, would be at 10mL or 5.00 x 2.
SUPER CONCENTRATE: (example CX4 or CX4S)
If you were to test the water output at 40:1, you would see by the chart that a total volume
of 29.3mL would be dispensed. The cleaner, which puts out 8 times the amount during the
test, would be at 5.60 or .70 x 8.
To set a different ratio other than what is being used in
your daily use, go to the PRESET ADJUSTMENT screen
explained on the following pages in this manual.
By pressing GO TO PRESET ADJUSTMENTS you will
advance to the screen that is used to set all the presets at
the factory. It is best to test the presets that are normally
used for proper ratio.
By pressing on Ratio Chart you will go to a screen that list the presets and the result you
should see in a test.
IMPORTANT: When making changes to the volume from this screen it will change ALL preset
ratios equally.
When testing Regular Concentrate, the pump will run a set number of board counts from the
board counting sensor
2 times the normal run compared to the water test because of the
low volume
used.