Problem
:
Oil Head Motor runs, but Input 001 does not operate when oil head is moving or it was
interrupted.
Possible Cause
:
 Board counting sensor has failed.
 Wire between sensor and PLC is damaged or loose causing an open connection.
 Motor is starting too slow due to lack of lubrication on the oil and cleaner sliding
head bars.
 Cleaner belt jumped timing causing the cleaner head to jam against the wall of the
machine. A set screw can come loose resulting in this problem.
Problem
:
Oil Head Motor does not run in one or both directions.
Possible Cause
:
 Motor has failed.
 Motor brushses worn. Remove/inspect and blow out motor.
 Motor unplugged or has a damaged wire.
 PLC output 101CH 00 has failed causing no operation.
 PLC output 101CH 01 has failed causing no operation right to left.
Normally, this error screen occurs when Input 009 is not turned on. Either Drive Board can
cause this error.