Technical data
6.4 200 V converters
Table 6- 10
PM240-2, PT, frame size D, 200 V ... 240 V 3 AC
Article No. without filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss
Required cooling air flow
Weight
approx. 0.72 kW through the heatsink
1)
Table 6- 11
PM240-2, IP20, frame size E, 200 V ... 240 V 3 AC
Article No. without filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss
Required cooling air flow
Weight
84
6SL3211-1PC26-8UL0
18.5 kW
64 A
68 A
15 kW
56 A
54 A
3NA3830 (100 A)
90 A
0.82 kW
1)
55 l/s
19.5 kg
6SL3210-1PC28-0UL0
22 kW
76 A
80 A
18.5 kW
71 A
68 A
3NA3830 (100 A)
100 A
0.92 kW
83 l/s
26.8 kg
6SL3210-1PC31-1UL0
30 kW
98 A
104 A
22 kW
83 A
80 A
3NA3836 (160 A)
150 A
1.28 kW
83 l/s
26.8 kg
Hardware Installation Manual, 01/2020, A5E33294624B AL