PG9602™ OPERATION AND MAINTENANCE MANUAL
COMMAND
DIFLOAD
DIFOFFSET(=)
DIFSETUP
DUTHEIGHT(=)
ERR
LOCALG(=)
LOCAL
MASSSETx(=)
MASSx(=)
MASS(=)
MEDIA(=)
MEM
MMODE(=)
MRES(=)
MROT(=)
MR
MS=
OHMS
PASSTHRUx
PCTx(=)
PGEN(=)
PISTONRDYx(=)
PISTONVARx(=)
PISTONx(=)
PISTON(=)
PPC=
PPCPR
PPOS
PR
PRTPCn
PS=
READYx(=)
READYCK(=)
REMOTE
RESET
RESUME
RESUME(=mode)
SETUP(=)
SN
SPEED
TIME(=)
UCOEF
UDD(=)
UDU(=)
© 2011 Fluke Calibration
Execute the mass load determined by the DIFSETUP command
Read or set the differential mode RPM offset value
Prepare PG7601 to determine the differential mode RPM offset
Set or read the DUT head height
Read the last error message
Set or read the local gravity
Local operation
Set or read the mass set values
Set or read the mass set data
Set or read the selected mass set
Set or read the DUT head medium
Read the memory OK flag
Set or read the measurement mode
Set or read the mass loading resolution
Set or read the manual motorized rotation status
Read the current mass load
Specify a new mass target, loading masses if AMH enabled
Read the ambient PRT and piston-cylinder PRT resistance
Allow the host PC to communicate with a device connected to the PG9000 COM
ports.
Set or read the source for the piston-cylinder temp
Set or read the automated pressure generation setting
Set or read piston rotation rate limits.
Set or read additional piston variables
Set or read the piston header information
Set or read the piston in use
Send a command to an external pressure generation/control component.
Read the pressure measured by a PPC pressure controller connected to
PG9000's COM3.
Read the current piston position
Read the current PG9000 defined pressure and "ready" status
Set or read the piston cylinder temperature PRT information
Specify a new PG9000 target pressure, loading masses if AMH enabled
Set or read the ready criteria for a specific "Setup"
Set or read the ready check flag status
Set the PG9000 into local lockout condition
Set basic PG9000 operating conditions to default.
"Reset, Sets".
Resume the suspended process of setting a new pressure by remote command.
Set the resume mode, which determines whether a pressure setting process
initiated by remote command will pause after target entry and require the
RESUME command to continue .
Set or read the setup to use
Read the PG9000 serial number
Read the piston rotation speed
Set or read the current time
Read the current pressure units conversion coefficient
Set or read the user defined external barometer settings
Set or read the user defined pressure unit
122