The FI-3000 and FI-3000-NW FiberInspector Pro (the Product or Probe) are hand-
held video probes used with a Versiv™ Series tester (the Tester) or with the
FI-IN™ app (the App) on a mobile device to inspect fiber optic endfaces. The
Probe and Tester or App let you see dirt, scratches, and other defects that can
cause unsatisfactory performance or failures in fiber optic networks.
Use the Probe with a direct USB connection to a Tester to view and analyze
endfaces and save and share test results. To do this wirelessly, use the FI-3000
probe with the App. The FI-3000-NW probe cannot be used with WiFi or the
App.
Safety Information
A Warning identifies hazardous conditions and procedures that are dangerous
to the user. A Caution identifies conditions and procedures that can cause
damage to the Product or the equipment under test.
To prevent possible electrical shock, fire, or personal injury and for safe
operation of the Product:
Read all safety information before you use the Product.
Carefully read all instructions.
Do not alter the Product and use only as specified, or the protection
supplied by the Product can be compromised.
Do not use the Product if it operates incorrectly.
Do not use the Product if it is altered or damaged.
Disable the Product if it is damaged.
English
PN 5003251
January 2019 Rev. 2, 2/20
© 2019-2020 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
FI-3000/FI-3000-NW
FiberInspector™ Pro
Getting Started Guide
XWWarning

Advertisement

loading
Need help?

Need help?

Do you have a question about the FiberInspector Pro FI-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fluke FiberInspector Pro FI-3000

  • Page 1 Do not use the Product if it is altered or damaged. • Disable the Product if it is damaged. English PN 5003251 January 2019 Rev. 2, 2/20 © 2019-2020 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 2 years of heavy use. Moderate use is defined as recharged twice a week. Heavy use is defined as discharged to cutoff and recharged daily. To replace the battery, send the Product to an authorized Fluke Networks Service Center. •...
  • Page 3: Charge The Battery

    Symbol Description 40 year Environment Friendly Use Period (EFUP) under China Regulation - Administrative Measure on the Control of Pollution Caused by Electronic Information Products. This is the period of ‡ time before any of the identified hazardous substances are likely to leak out, causing possible harm to health and the environment.
  • Page 4 Attach the Correct Tip MPO Tips and Adapters Key Left Key Right Single Fiber Adapters and Tips...
  • Page 5 Use the Probe with a Tester Set up the Probe and Tester Select Test Settings and Set Key Position on the Tester On the home screen, tap the test setup panel (The panel below where it says PROJECT). Tap NEW TEST > Module > FiberInspector Pro. The TEST SETUP screen shows on the display.
  • Page 6 Inspect Endfaces Insert the probe into a bulkhead or patch cord adapter. Tap TEST on the Tester, or push on the Probe to view a live image of the endface on the display. On the Tester, tap ANALYZE. For MPO tests: The fiber numbers on the image of the endface on the display agree with the fiber locations on the connector.
  • Page 7 Use the Probe with a Mobile Device >2 s Android FI-3000... 1234567890...
  • Page 8 Select Test Settings and Set Key Position in the App & > (Current Project). To create a new project, tap (Manage Projects) > (Add). Select settings as necessary, and tap Save. For MPO tests: (Key). Select Key Left or Key Right to agree with the key position of the tip on the probe.
  • Page 9: Learn More

    To read articles in the Knowledge Base, visit www.flukenetworks.com/ knowledge-base. To request a printed manual, visit www.fluke.com/productinfo. Registration Registering your product with Fluke Networks gives you access to valuable information on product updates, troubleshooting tips, and other support services. To register the Probe: Go to www.flukenetworks.com...
  • Page 10: Contact Fluke Networks

    1-800-283-5853, +1-425-446-5500 Fluke Networks 6920 Seaway Boulevard, MS 143F Everett WA 98203 USA Fluke Networks operates in more than 50 countries worldwide. For more contact information, go to our website. General Specifications Battery Lithium-ion, 3.6 V, 6400 mAh AC power adapter Input 100 VAC to 240 VAC ±10 %, 50/60 Hz...
  • Page 11 SIMPLIFIED EU DECLARATION OF CONFORMITY The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows: Hereby, Fluke Networks declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full...
  • Page 12 License (GPL) or Lesser GNU General Public License (LGPL)”, the complete corresponding sources are available. You can order a complete machine- readable copy of the source code from Fluke Networks for a period of three (3) years after receipt of the product. Send a written request to:...

This manual is also suitable for:

Fiberinspector pro fi-3000-nw