 After installation of each peripheral device, do some test
prints and check for the presence of skew, and check that
side-to-side registration is correct.
 When you detect a problem with skew or side-to-side
registration, do the adjustment on the joint bracket
attached to the peripheral unit upstream of the unit where
the problem occurred.
 Side-to-side registration is corrected by shifting the
 Skew is eliminated by inserting spacers (shims) under the
rear or front end of the joint bracket. These attached by
screws to the peripheral units before they leave the factory.
 Before adjusting skew or registration manually, be sure to
enter the SP mode and set SP1206 to "2" (OFF).
 When you are finished, re-set SP1206 to "1".
 This is a Taurus SP – not sure what the correct SP is for
Slide 132
No additional notes

Outline of the Procedure

upstream joint bracket left or right.