When Skew Should Be Adjusted - 1
Look at the scale when the leading edge comes by and when the
trailing edge comes by.
Check where the side edge of the paper is on the scale.
If the side of the paper comes past at the same place on the scale,
The above diagram shows an example where no adjustment is
If the error is more than ±2 mm, you should adjust the machine.
Adjust for skew first, then for registration shift.
Slide 137
LE: Leading edge
TE: Trailing edge
To check for skew
Look at the scale when the leading edge comes by and when the trailing
edge comes by. Check where the side edge of the paper is on the scale.
If the side of the paper comes past at the same place on the scale, there is
no skew.
If the difference is more than 2 mm, you should adjust the machine.
DLT
TE
LE
there is no skew.
necessary.
A3
DLT
TE
LE
137
Ch-C1 Training
A3