The UNIGATE® IC
2
The UNIGATE
2.1

Technical introduction

®
The UNIGATE
IC2 by Deutschmann Automation contains all components that are required for
the communication in a fieldbus in one single module. Therefore a developer does not have to
take care for that detail any more, only a hardware redesign is necessary in order to integrate the
®
UNIGATE
IC2 and the required plug connectors.
2.2

Availability

The module is available as Ethernet. Further fieldbuses are either planned or being worked on.
They will only differ in the connections of the busses. The meaning of the general pins 1 - 9 as
well as 24 and 26 - 32 will remain unchanged also for further fieldbus implementations.
You can find an up-to-date list for all UNIGATE
http://www.deutschmann.com.
2.3

Firmware

®
UNIGATE
IC2 is programmed via Scripts. On principle any Script, that has been developed for
®
a UNIGATE
IC2, can also be operated on the UNIGATE
2.4

The serial standard interface

Intelligent devices, that already feature a micro controller or a microprocessor, are generally sup-
plied with a serial asynchronous interface with a TTL-level. It is directly connected with the TTL-
interface of the UNIGATE
2.5

The synchronous serial interface

In addition to the standard interface there is also the possibility of the synchronous input and out-
put. That way for instance digital IOs can be connected through shift register components or also
analog IOs can be connected through a DA-converter with serial in-/output. For synchronous IOs
256 signals at the most can be used (256 bit). Wiring examples can be found in chapter 3.5 and
for software examples see chapter 5. This interface can also be used to connect modules or
devices with SPI-interface. It is also possible to build, for instance digital or analogous I/O-mod-
ules, with the customer's device not being equipped with an own controller. The fieldbus IC2 is
also operable autonomously without that controller.
2.6

The Debug-interface

®
The UNIGATE
IC2 features a Debug-interface, which allows to process a Script step by step
and also to monitor or manipulate data. This is indispensable for the development of a Script.
Usually a Script is developed with the software Protocol Developer. For more details take a look
at the instruction manual Protocol Developer.
All interfaces can independently be used at the same time.
11
Instruction manual UNIGATE
IC
®
®
®
IC2. For more information on this serial interface see chapter 4.