TEXI Catenaccio operation manual
4. The moving knife and counter knife
5. Needle thread clamp device
Turn OFF the power before starting the work so as to prevent accidents cause by
abrupt start of the sewing machine.
Turn OFF the power before starting the work so as to prevent accidents cause by
abrupt start of the sewing machine.
1. Loosen adjusting screw (3) so that a clearance of 18.5
mm is provided between the front end of the throat
plate and the top end of thread trimmer lever, small
(1). To adjust, move the moving knife in the direction
of arrow.
2. Loosen setscrew (5) so that a clearance of 0.5 mm is
provided between needle hole guide (2) and counter
knife (4). To adjust, move the counter knife.
1. When thread is caught at top end (1) of the thread
clamp, thread clamp becomes incomplete and sewing
trouble at the sewing start will be caused.
Remove it with tweezers or the like.
2. When removing thread waste or thread dust collected
on the thread clamp device, remove it after removing
the throat plate.
42