Radware AppDirector OnDemand Switch VL Installation And Maintenance Manual page 75

Table of Contents

Advertisement

Table 16: General Specifications of OnDemand Switch 3 Platforms
Item
Dimensions
Weight
Environmental
Auto-range supply
Power consumption
Heat dissipation
CPU temperature
Certifications
1 – For more information, see
page
77.
2 – For OnDemand Switch 1, 1 XL, 2, 2XL, and 3 models only.
3 – For OnDemand Switch 3 and single AC PS 2 only.
Document ID: RDWR_APD_IG_1304
OnDemand Switch 3 Specification
1U:
Width: 424 mm (17 in.)
Depth: 600 mm (24 in.)
Height: 44 mm (1.7 in.)
2U:
Width: 424 mm (17 in.)
Depth: 600 mm (24 in.)
Height: 88 mm (3.4 in.)
EIA rack or stand-alone: 483 mm (19 in.)
OnDemand Switch 3: 15.0 kg (33.0 lbs)
OnDemand Switch 3 XL: 15.1 kg (33.3 lbs)
OnDemand Switch 3 v.2: 15.0 kg (33.0 lbs)
Operating temperature: 0 ºC to 40 ºC (32 ºF to 104 ºF)
Humidity: 5% to 95% non-condensing
AC: 100V–240V, 47Hz–63Hz
DC: –36V~–72V
Dual power supply (AC/DC) in 2U form for relevant models
AppDirector 8016–16016 with 8 GB RAM: 343 W
AppDirector v.2 with 16 GB RAM: 488 W
AppDirector XL with 16 GB RAM: 510 W
AppDirector 8016–16016 with 8 GB : 1170 BTU/h
AppDirector v.2 with 16 GB RAM: 1664 BTU/h
AppDirector XL with 16 GB RAM: 1739 BTU/h
SNMP traps are sent in response to high temperatures:
Warning: 69 ºC
Critical: 74 ºC
Note:
When the platform reaches the critical temperature, it will
automatically shut down.
Safety: EN 60950-1:2006, CB - IEC 60950-1, cTUVus, CCC, cULus
EMC: CE - EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3, IEC
61000 4-2 to 4-6, IEC 61000 4-8 and IEC 61000-4-11, FCC
Part 15B Class A, KCC
RoHS 6 Compliant
Platforms, page 27
AppDirector Installation and Maintenance Guide
3
, ICES-003, VCCI Class A, C-Tick
and
Transceiver-Module Specifications,
Specifications
2
75

Hide quick links: