Simple DFC (Simple-Fill)

In this mode, the 100 memory ID locations are unavailable. The MEM and
RECALL keys will have no functionality. This mode also will default to a 2-speed,
chatter gate operation (non-selectable) with no auto-trim. This mode is useful
when ID storage and weight accumulations are not needed, but the ability to
quickly change target fill weight is required.
Recommended Settings:
D OUT=
FMODE=1
FIL-AA=
PURGE=
P-WGT=
SPEED=
CHATR=
CHTOFF
TRMWT=
A-PRNT=
DFCEND
DFC Preset Setup Procedure (Load & Unload Mode):
Page 110
4 (Required) or 14 (Required for inverted outputs)
(Required for Simple-Fill)
YES for each completed fill weight to be added to an accumulator
N Where N the number of fill cycles you require before a manual feeder
purge will take place. Set to 0 to disable
This is the weight of material contained within the feeder you will be
purging.
1 (discharge motor only has 1 speed) or 2 (discharge motor is 2 speed)
This is the amount of time (in seconds) the output will be active when
chattering.
This is the amount of time (in seconds) the output will be inactive when
chattering.
This is the trim weight. Target weight – trim weight = weight at which
chattering will begin.
YES If using a printer, this will automatically print at the end of a fill cycle
YES If you want the indicator to display DONE upon completion of a fill
cycle.
1. Verify your desired fill weight is stored in the indicator by pressing
the PRESET key.
2. The display will read FILL= . This is the target fill weight. Press the
ENTER key to display the current value. If this value is correct,
press the ENTER key to accept otherwise key in your desired fill
weight then press ENTER.
8200-M639-O1 Rev D 09/14