The Cardinal 212/212X Weight Indicator is equipped with diagnostic
software program that tests various portions of the indicator's circuitry and
verifies proper operation. Should a problem be detected or an error in the
operation occur, an error or status message will be displayed alerting the
operator to that condition. The following lists the error and status
messages displayed and their meaning.
Display
Message
A. An illegal function was performed or an invalid keypad
Error
entry was attempted.
1.
2.
3.
4.
5.
6.
7.
B. Determine which of the reasons for the error display is
applicable and take the appropriate corrective action.
paused
A. This message is displayed to indicate a digital fill cycle
has been paused.
B. Press the HOLD key to resume fill or the  key to abort
the fill.
Cause (A.) and Corrective Action (B.)
The TARE key was pressed to enter a push button
tare with a negative weight.
An attempt was made to enter a tare weight value
that exceeds the scale capacity.
Attempting to enter a Tare weight value that is
inconsistent with the scale division value. (e.g.
entering a tare of 3 lbs with scale divisions of 5 lbs).
Attempting to tare scale when there is motion
present or the Gross weight is below zero or over
capacity.
Attempting to print when scale is over capacity or a
negative weight.
Attempting to zero scale when there is motion
present or the scale is over capacity.
Attempting to start the Digital Fill Control in the
Unload mode when there is not enough material on
the scale to complete a fill cycle.