Assembly
Heatsink and Fan
X
X
Config 2: Fan on the left and heatsink on the right
x2
Orient the fan bracket as illustrated.
Insert the zinc-coated screws from the
exterior and fasten them tight onto the
chassis and the bracket.
When installed correctly, the locations
of the bracket and the screws shall
resemble the following photos.
User's Manual | OPS150-CS
Screws
Step 2: Heatsink Installation
Install/remove the heatsink by screwing/unscrewing two of the spring screws at opposite cor-
ners, and then proceed with the other two spring screws. Please make sure the system board
is secured onto the base of the chassis before installing the heatsink.
Orient the heatsink so that it is seated in correspondence to the configuration of your choice.
Config 1: Fan on the right
and heatsink on the left
Important:
Since the springs of the screws are highly resilient and lopsidedness of the
screwed-on heatsink may cause uneven pressure and possible damage to the CPU
and board, it is highly suggested that, during the installation/disassembly, the heat-
sink is applied additional pressure to remain parallel to the board.
Chapter 2
HARDWARE INSTALLATION
Config 2: Fan on the left and
heatsink on the right
12