Page 2
AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this document. AXIOMTEK makes no commitment to update or to keep current the information contained in this manual. AXIOMTEK reserves the right to make improvements to this document and/or product at any time and without notice.
Page 3
Table of Contents Chapter 1 Introduction ---------------------- iv Specifications ............1 Chapter 2 Hardware Setting -------------------3 System Connection Diagram ........ 3 HARDWARE LAYOUT ......... 3 Table of Contents...
Page 4
This page does not contain any information. Table of Contents...
DB-87040 / DB-87060 User’s Manual C h a p t e r Introduction DB-87040 and DB-87060 are a general terminal board for 4 axes and 6 axes motion controls, respectively. They are convenience and efficiency for connecting the 4/6-axes motion control card with external devices such as servo drive, encoder, local I/O and DAC signal.
Page 6
DB-87040 / DB-87060 User’s Manual 4-axes or 6-axes motion control wiring signals Connector: SCSI-II 100-pin pin type Signal: 4-axes or 6-axes motion control board signals Dedicated Digital Input and Output D/I Signal: HOME, OT+, OT-, STOP (Emergency Stop) D/O Signal: INH (Output Inhibits) and RDY (Servo Ready)
DB-87040 / DB-87060 User’s Manual C h a p t e r Hardware Setting System Connection Diagram DDA x 6 , ENC x 6, LIO x 26, D/A x 6 DASP52506 DB-87060 Terminal Board 6 servo motors (For Example: DB-87060 Terminal Board)
Page 9
DB-87040 / DB-87060 User’s Manual HOM3 OT+3 OT-3 HOM2 OT+2 OT-2 HOM1 OT+1 OT-1 RDY+, RDY-: Output Servo Ready Signal STOP: Emergency Stop Input Signal OT+n, OT-n: Input Inhibit Signal from the nth Axes HOMn: Input Home Signal from the nth Axes...
Page 10
DB-87040 / DB-87060 User’s Manual RDY digital output (C). Switch – SW1, SW2, SW3, SW4, SW5, SW6 Definition HOME MODE Default HOME : Parallel connection with TB1. HOME should be set OFF when it connected with the external HOME Sensor. The Dip Switch is simulated as the external Home Sensor when the actual external Home Sensor is not connected.
Page 11
DB-87040 / DB-87060 User’s Manual the simulated OT+ Sensor is enabled and OFF indicates disable. OT- : Parallel connection with TB1. OT- should be set OFF when it connected with the external OT- Sensor. The Dip Switch is simulated as the external OT+ Sensor when the actual external OT- Sensor is not connected.