Appendix C: Loop Device Address Setting - Zeta Alarm Systems SMARTCONNECT SMART6 Installation Manual

Multi-loop panel
Table of Contents

Advertisement

Smart Connect Multi-loop Installation Manual
SCM-MIM
Multi Input Module
SCM-ZMM
Zone Monitor Module
SCM-RM
Multi Relay Module
SCM-ACM
Alarm Circuit Module
SCM-NM
Network Module - RS485
SCM-PM
RS232 Module (Printer Driver)
MKII-AOP
MKII Addressable Optical Smoke Detector
MKII Addressable Combined Optical Smoke & Heat (A1R)
MKII-AOH
Detector
MKII-AHF
MKII Addressable Fixed Heat Only A2S Detector
MKII-AHF/CS90
MKII Addressable Fixed Heat Only CS Detector
MKII-AHR
MKII Addressable RoR & Fixed Heat Detector A1R Detector
MKII-AOPI
MKII Addressable Optical Smoke Detector With Built-In Isolator
MKII Addressable Combined Optical Smoke & Heat (A1R)
MKII-AOHI
Detector With Built-In Isolator
MKII Addressable Fixed Heat Only A2S Detector With Built-In
MKII-AHFI
Isolator
MKII Addressable Fixed Heat Only CS Detector With Built-In
MKII-AHFI/ CS90
Isolator
MKII Addressable Rate of Rise & Fixed Heat Detector A1R
MKII-AHRI
Detector With Built-In Isolator
MKII-ARL
MKII Addressable Remote LED Indicator
ZT-CP3/AD
Addressable CP3 Manual Call Point
ZAI-MI
MKII Addressable Input Module with S/C Isolator
ZAIO-MI
MKII Addressable Input/Output Module with S/C
ZASC-MI
MKII Addressable Sounder Circuit Controller with S/C Isolator
ZAZM-MI
MKII Addressable Zone Monitoring Unit with S/C Isolator
ZAIO/230
MKII Addressable Mains switching Input/Output Module
SMM/B
Special Mini Modules (White) - Beam Detector
MKII-SSB
MKII Sandwich Sounder (No Address Required)
MKII-AXT
MKII Addressable Xtratone Wall Sounder
MKII-AXTB
MKII Addressable Xtratone Combined Sounder Beacon
ZRAP
MKII Addressable Raptor Weatherproof Sounder
ZRAPB
MKII Addressable Raptor Weatherproof Sounder Beacon
MKII-OP
MKII Conventional Fyreye Optical Smoke Detector
MKII-HR
MKII Conventional Fyreye ROR Heat Detector
MKII-HF
MKII Conventional Fyreye Fixed Heat Detector
MKII-HF-CS90
MKII Conventional Fyreye Fixed Heat (CS) Detector
MKII-OH
MKII Conventional Fyreye Opto-Heat Detector
MKII-RL
MKII Conventional Remote LED Indicator
ZXT
Xtratone Conventional Wall Sounder
ZXTB
Xtratone Conventional Combined Wall Sounder Beacon
ZRP
Conventional Raptor Sounder
ZRPB
Conventional Raptor Sounder Beacon
*Loop device current and alarm current not included. On batteries use 1.5x current to allow for DC-DC step up voltage
**Current for printing out alarm message not included
***Depends on flasher intensity setting
****For use with either SCM-ZMM, or the MKII-ZAZM loop powered module

Appendix C: LOOP DEVICE ADDRESS SETTING

Soft Addressing (with handheld programming tool)
The MKII Handheld Programmer is designed to complement all MKII devices and to assist the commissioning engineer on site. The unit
will softly address all devices without using the incorporated dip-switch on the field devices.
www.zetaalarmsystems.com
48
73
62
97
28
116
32
32+ alarm load
37
37**
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.5
5
0.45
2.3
1
3.6
1
2
0.6
0.8
3.5
13.2
1.5
4.6
1.1
12
0.65
5.5
1.5
5.4
1.5
19-44***
1.5
5.4
1.5
19-44***
0.07
35-45****
0.07
35-45****
0.07
35-45****
0.07
35-45****
0.07
35-45****
0.45
2.1****
0
10
0
60-70***
0
10
0
60-70***
43

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTCONNECT SMART6 and is the answer not in the manual?

Questions and answers

Sanoop
April 18, 2025

How to identify double address detector

User image 6802a93cb31b4
1 comments:
Mr. Anderson
May 10, 2025

To identify a double address detector in the Zeta Alarm Systems SMARTCONNECT SMART6, check the DIP switch address settings. A double address detector will respond to two consecutive addresses. If two detectors are configured with the same DIP switch settings or respond to the same address, this indicates a double address condition. Use the DIP switch table to verify that each detector has a unique address.

This answer is automatically generated

Table of Contents

Save PDF