PSU Fuses

All fuses are quick blow, rating as shown.
Panel Designation
Fuse A
Fuse B
Fuse C
Fuse D
Fuse E
Fuse F

Power Supply Status Indications

LED
LED
Description
Colour
AC Power ON
Green
DC Power ON
Green
Charger Fault
Yellow
Battery Fault
Yellow
Battery Hi Z
Yellow
Blown Fuse
Yellow
1.
Switch SW2 on the charger PCB is used to determine if temperature compensation is used or not.
Power down panel completely before removing cover to change the setting.
2.
Battery circuit resistance measurement is required by BS EN 54-4. The maximum resistance of several
tens to hundreds of milliohms varies for different power supplies and depends on their nominal
output voltage and power. It can be set on or off by using switch 4 of dip switch SW1 on the charger
PCB. Power down panel completely before removing cover to change the setting.

Power Supply Signals

Description
MAINS FAULT
FAULT RELAY
PSU DATA
www.zetaalarmsystems.com
SMART6
1A
1A
7.5A
7.5A
5A
3.15A
Indication
Event
Method
ON
Mains power present, converter in operating state
OFF
Mains power off
ON
No mains power or converter off
OFF
When mains power present
OFF
Normal
Flashing
Charger Fault
OFF
Normal
Battery disconnected /
Flashing
Battery fuse blown or removed/
Low Battery
OFF
Normal
Flashing
Battery internal high impedance present
OFF
Normal
Flashing
Fuse A, B, C, or D, are blown
Details
Continuity between NC & C in normal operating condition. When there is a fault condition on the
mains power, continuity is switched to NO & C. Relay is normally energized and "fail-safe" as the
relay will change over in the event of total power failure.
Continuity between NC & C in normal operating condition. When there is any fault on the PSU or
Charger, continuity is switched to NO & C. Relay is normally energized and "fail-safe" as the relay
will change over in the event of total power failure.
Serial data connection from PSU to termination PCB. TO BE USED TO CONNECT TO PANEL ONLY.
SMART10
SMART26
1A
1A
1A
1A
7.5A
7.5A
7.5A
7.5A
8A
15A
3.15A
3.15A
38

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTCONNECT SMART6 and is the answer not in the manual?

Questions and answers

Sanoop
April 18, 2025

How to identify double address detector

User image 6802a93cb31b4
1 comments:
Mr. Anderson
May 10, 2025

To identify a double address detector in the Zeta Alarm Systems SMARTCONNECT SMART6, check the DIP switch address settings. A double address detector will respond to two consecutive addresses. If two detectors are configured with the same DIP switch settings or respond to the same address, this indicates a double address condition. Use the DIP switch table to verify that each detector has a unique address.

This answer is automatically generated

Subscribe to Our Youtube Channel

Table of Contents

Save PDF